Evaluation of a Chemiluminescent Immunoassay for Measurement of Equine Insulin

نویسندگان

  • H.B. Carslake
  • G.L. Pinchbeck
  • C.M. McGowan
چکیده

BACKGROUND Many diagnostic tests for insulin dysregulation use reference intervals established with an insulin radioimmunoassay (RIA) that is no longer available. A chemiluminescent immunoassay (CLIA) is commonly used for the measurement of serum insulin concentration in clinical practice but requires further validation, especially at clinically relevant reference intervals. OBJECTIVES To evaluate the CLIA for measurement of equine insulin and compare it to the previously validated, but now unavailable RIA. SAMPLES Equine serum samples (n = 78) from clinical and experimental studies. METHODS In this experimental study, performance of the CLIA was evaluated using standard variables, including comparison with the RIA. Continuous and binary outcomes were analyzed. RESULTS The CLIA showed good intra-assay (coefficient of variation [CV], 1.8-2.4%) and interassay (CV, 3-7.1%) precision. Acceptable recovery on dilution (100 ± 10%) was achieved only at dilutions <1:1. Recovery on addition was acceptable. Comparison of the CLIA and RIA showed strong positive correlation (r = 0.91-0.98), with fixed and proportional bias. At 3 diagnostic cutoffs, sensitivity of CLIA compared with RIA ranged from 67 to 100% and specificity from 96 to 100%. CONCLUSIONS AND CLINICAL IMPORTANCE The CLIA is a highly repeatable assay which is suitable for within- and between-horse comparisons. Dilution of high concentration samples should be performed with charcoal-stripped serum (CSS) and at the lowest dilution factor possible. At concentrations commonly used for diagnosis of insulin dysregulation (≤100 μIU/mL), results from the CLIA tend to be lower than from the RIA and should be interpreted accordingly. Further standardization of equine insulin assays is required.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the PATHFAST Chemiluminescent Enzyme Immunoassay for Measuring Progesterone in Whole Blood and Serum of Mares

Evaluation of a new chemiluminescent enzyme immunoassay, the PATHFAST assay system (PATHFAST), for measurement of circulating progesterone in mares was performed. Five mares at the mid-luteal stage were administrated a single i.m. injection of prostaglandin F2α analog (PGF2α; cloprostenol 250 μg/ml), and then blood samples were collected from the jugular vein at 0, 15, 30 and 45 min, at one-hou...

متن کامل

Comparison of three different methods for the quantification of equine insulin

BACKGROUND Exact analysis of equine insulin in blood samples is the key element for assessing insulin resistance or insulin dysregulation in horses. However, previous studies indicated marked differences in insulin concentrations obtained from sample analyses with different immunoassays. Most assays used in veterinary medicine are originally designed for use in human diagnostics and are based o...

متن کامل

PATHFAST, a novel chemiluminescent enzyme immunoassay for measuring estradiol in equine whole blood and serum

A novel chemiluminescent enzyme immunoassay system, PATHFAST, for the measurement of estradiol in horses was evaluated. The concentrations of estradiol in the whole blood and serum of mares were measured using PATHFAST and the estradiol concentrations measured by PATHFAST were compared with those measured by a time-resolved fluoro-immunoassay (FIA). To monitor physiological changes, serum estra...

متن کامل

Performance evaluation and cross-reactivity from insulin analogs with the ARCHITECT insulin assay.

BACKGROUND Insulin measurement is used for the diagnosis of hypoglycemia and for insulin pharmacokinetic evaluations. We assessed the analytical and clinical performance of the ARCHITECT insulin assay, a chemiluminescent immunoassay recently introduced for the ARCHITECT i2000 fully automated immunoassay analyzer (Abbott Laboratories). We also tested whether major insulin analogs cross-reacted w...

متن کامل

On-line computer analysis of chemiluminescent reactions, with application to a luminescent immunoassay for free cortisol in urine.

We interfaced a microcomputer on-line with a luminometer to acquire the light signal of chemiluminescent reactions from a photomultiplier and then compute significant parameters of light emission and kinetic "shape" indices. Using this system to study interferences from biological samples on the measurement of chemiluminescent reactions, we observed that such effects are usually associated with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 31  شماره 

صفحات  -

تاریخ انتشار 2017