Is DWI/ADC a Useful Tool in the Characterization of Focal Hepatic Lesions Suspected of Malignancy?

نویسندگان

  • Maria Luiza Testa
  • Rubens Chojniak
  • Letícia Silva Sene
  • Aline Santos Damascena
  • Marcos Duarte Guimarães
  • Janio Szklaruk
  • Edson Marchiori
چکیده

OBJECTIVE Apparent diffusion coefficient (ADC) values calculated through magnetic resonance imaging have been proposed as a useful tool to distinguish benign from malignant liver lesions. Most studies however included simple cysts in their analysis. Liver cysts are easy to diagnose, have very high ADC values and their inclusion facilitates differentiation in the ADC values between benign and malignant liver lesions groups. We prospectively evaluated the ability of ADC values to differentiate metastatic liver lesions from all benign or only solid benign liver lesions. MATERIAL AND METHODS Sixty-seven adult cancer patients with 188 liver lesions were evaluated. Lesions were categorized as metastatic or benign throughout imaging and clinical evaluation. One hundred and five (105) metastatic lesions and 83 benign lesions including hemangiomas (37), cysts (42), adenomas (2) and focal nodular hyperplasias (2) were evaluated. ADC values were calculated for each lesion utilizing two b values (0 and 600 sec/mm2). RESULTS The average ADC value for cysts was 2.4×10(-3) mm2/sec (CI: 2.1-2.6), for solid benign lesions was 1.4×10(-3) mm2/sec (CI: 1.1-1.7) and for metastases was 1.0×10(-3) mm2/sec (CI: 0.8-1.3). There was a difference between the ADC values of metastases and benign solid lesions (p<0.0001). With the ADC value of 1.5×10(-3) mm2/sec as a cut off it is possible to distinguish metastatic from benign liver lesions, including cysts, with an accuracy of 78%. But to distinguish metastatic from benign solid liver lesions the best ADC cut off value was 1.2×10(-3) mm2/sec and the accuracy drops to 71%. CONCLUSIONS ADC values proved to be helpful in the distinction between metastasis and benign solid hepatic lesions. But the exclusion of cysts in the analysis point out to a lower cut off value and lower accuracy than previously reported.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diffusion Weighted MR and Apparent Diffusion Coefficient Measurement in Classification and Characterization of Noncystic Focal Liver Lesions: Does a Clinical Role Exist?

The objective of this study was to assess the clinical role of apparent diffusion coefficient (ADC) analysis in noncystic focal liver lesion (FLL) classification/characterization.Six hundred liver magnetic resonances with multi-b (b = 50, 400, 800 s/mm) diffusion-weighted imaging (DwI) were retrospectively reviewed. Mean ADC was measured in 388 lesions (195 benign and 193 malignant) excluding i...

متن کامل

DWI/ADC in Differentiation of Benign from Malignant Focal Liver Lesion

MATERIAL AND METHODS The study was of prospective-retrospective character. It was carried out at the AKH in Vienna (Austria), where 100 patients with focal liver lesions were included in the study. All patients underwent the routine MR sequences on appliances 1,5 and 3T (Siemens, Germany): T1, T2, HASTE, VIBE, and a DWI with three b values (b 50, b 300 b 600 s / mm2) and ADC map with ROI (regio...

متن کامل

Assessment of diagnostic value of DWI technique in the evaluation of liver fibrosis

Introduction: The liver fibrosis is caused by extracellular accumulation of cluster, glycos amino glycans and proteoglycans, which this extracellular accumulation may limit the penetration and molecular movement of water in the tissue, so the Diffusion weighted imaging(DWI) technique is due to the sensitivity to the movement and release of water molecules Can show this restrict...

متن کامل

Evaluation the FLAIR Sensitivity and DWI Post-inject in Comparison with Delayed Enhancement T1w for Better Detection of Active MS Lesions

Background: Multiple sclerosis (MS) is a chronic, typically progressive and most common autoimmune disease which damaged the central nervous system. According to the reports in 2008, this disorder has affected 2 and 2.5 million people globally. While the reason is not clear, proposed causes for this include immunologic, environmental, infectious and genetic factors, and sexuality. MS can cause ...

متن کامل

I-47: Doppler Ultrasound Diagnosis of Intrauterine Lesions

Background In patients with abnormal uterine bleeding, transvaginal ultrasound (TVS) is the first-line diagnostic approach to exclude endometrial pathology. If a thickened endometrium suggests endometrial pathology, sonohysterography, office hysteroscopy or dilatation and curettage are the second-line tests preferred, depending on availability and on the suspected pathology, to exclude malignan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014