Tandem mass spectrometric analysis for amino, organic, and fatty acid disorders in newborn dried blood spots: a two-year summary from the New England Newborn Screening Program.

نویسندگان

  • T H Zytkovicz
  • E F Fitzgerald
  • D Marsden
  • C A Larson
  • V E Shih
  • D M Johnson
  • A W Strauss
  • A M Comeau
  • R B Eaton
  • G F Grady
چکیده

BACKGROUND Tandem mass spectrometry (MS/MS) is rapidly being adopted by newborn screening programs to screen dried blood spots for >20 markers of disease in a single assay. Limited information is available for setting the marker cutoffs and for the resulting positive predictive values. METHODS We screened >160 000 newborns by MS/MS. The markers were extracted from blood spots into a methanol solution with deuterium-labeled internal standards and then were derivatized before analysis by MS/MS. Multiple reaction monitoring of each sample for the markers of interest was accomplished in approximately 1.9 min. Cutoffs for each marker were set at 6-13 SD above the population mean. RESULTS We identified 22 babies with amino acid disorders (7 phenylketonuria, 11 hyperphenylalaninemia, 1 maple syrup urine disease, 1 hypermethioninemia, 1 arginosuccinate lyase deficiency, and 1 argininemia) and 20 infants with fatty and organic acid disorders (10 medium-chain acyl-CoA dehydrogenase deficiencies, 5 presumptive short-chain acyl-CoA dehydrogenase deficiencies, 2 propionic acidemias, 1 carnitine palmitoyltransferase II deficiency, 1 methylcrotonyl-CoA carboxylase deficiency, and 1 presumptive very-long chain acyl-CoA dehydrogenase deficiency). Approximately 0.3% of all newborns screened were flagged for either amino acid or acylcarnitine markers; approximately one-half of all the flagged infants were from the 5% of newborns who required neonatal intensive care or had birth weights <1500 g. CONCLUSIONS In screening for 23 metabolic disorders by MS/MS, an mean positive predictive value of 8% can be achieved when using cutoffs for individual markers determined empirically on newborns.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inherited Disorders of Intermediary Metabolism

■ Abstract This review is intended to serve as a practical guide for geneticists to current applications of tandem mass spectrometry to newborn screening. By making dried-blood spot analysis more sensitive, specific, reliable, and inclusive, tandem mass spectrometry has improved the newborn detection of inborn errors of metabolism. Its innate ability to detect and quantify multiple analytes fro...

متن کامل

Diagnosis and therapeutic monitoring of inborn errors of metabolism in 100,077 newborns from Jining city in China

BACKGROUND Mandatory newborn screening for metabolic disorders has not been implemented in most parts of China. Newborn mortality and morbidity could be markedly reduced by early diagnosis and treatment of inborn errors of metabolism (IEM). Methods of screening for IEM by tandem mass spectrometry (MS/MS) have been developed, and their advantages include rapid testing, high sensitivity, high spe...

متن کامل

Newborn screening for hepatorenal tyrosinemia: Tandem mass spectrometric quantification of succinylacetone.

BACKGROUND False-positive and false-negative results occur in current newborn-screening programs for hepatorenal tyrosinemia, which measure tyrosine concentrations in blood spots, sometimes in combination with other metabolites, including succinylacetone. We present our experience with a newly described method for succinylacetone quantification in routine newborn screening. METHODS Succinylac...

متن کامل

Evaluation of turbidimetric high-sensitivity C-reactive protein assays for cardiovascular risk estimation.

tions. J Chromatogr 1992;577:205–14. 11. Matsumoto I, Kuhara T. Inborn errors of amino acid and organic acid metabolism. In: Desiderio DM, ed. Mass spectrometry: clinical and biomedical applications, Vol. I. New York: Plenum Press, 1992:259–98. 12. Chace DH. Mass spectrometry in the clinical laboratory. Chem Rev 2001; 101:445–77. 13. Millington D, Chace D. Carnitine and acylcarnitines in metabo...

متن کامل

Tandem mass spectrometric analysis for disorders in amino, organic and fatty acid metabolism: two year experience in South Korea.

Seoul Clinical Laboratories began screening newborns and high risk group blood spots with tandem mass spectrometry (MS/MS) in April 2001. The goal was to determine approximate prevalence of metabolic disorders and optimization of decision criteria for estimation of preventive effect with early diagnosis. Approximately 44,300 neonates and children were screened and the estimated prevalence (newb...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 47 11  شماره 

صفحات  -

تاریخ انتشار 2001