EEG/MEC error bounds for a static dipole source with a realistic head model

نویسندگان

  • Carlos H. Muravchik
  • Arye Nehorai
چکیده

This work presents the background and derivation of Cramér-Rao bounds on the errors of estimating the parameters (moment and location) of a dynamic current dipole source using data from electro- and magneto-encephalography. A realistic head model, based on knowledge of surfaces separating tissues of different conductivities, is used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Error bounds for EEG and MEG dipole source localization.

General formulas are presented for computing a lower bound on localization and moment error for electroencephalographic (EEG) or magnetoencephalographic (MEG) current source dipole models with arbitrary sensor array geometry. Specific EEG and MEG formulas are presented for multiple dipoles in a head model with 4 spherical shells. Localization error bounds are presented for both EEG and MEG for ...

متن کامل

Influence of skull conductivity perturbations on EEG dipole source analysis.

PURPOSE Electroencephalogram (EEG) source analysis is a noninvasive technique used in the presurgical of epilepsy. In this study, the dipole location and orientation errors due to skull conductivity perturbations were investigated in two groups of three-dimensional head models: A spherical head model and a realistic head model. METHODS In each group, the head model had a brain-to-skull conduc...

متن کامل

The Realistic versus the Spherical Head Model in Eeg Dipole Source Analysis in the Presence of Noise

The performance of the three-shell spherical head model versus the performance of the realistic head model is investigated when solving the inverse problem with a single dipole, in the presence of noise. This is evaluated by inspecting the average dipole location error when applying a spherical and a realistic head model, for 1000 noisy scalp potentials, originating from the same test dipole an...

متن کامل

Effects of dipole position, orientation and noise on the accuracy of EEG source localization

BACKGROUND The electroencephalogram (EEG) reflects the electrical activity in the brain on the surface of scalp. A major challenge in this field is the localization of sources in the brain responsible for eliciting the EEG signal measured at the scalp. In order to estimate the location of these sources, one must correctly model the sources, i.e., dipoles, as well as the volume conductor in whic...

متن کامل

Realistic and Spherical Head Modeling for EEG Forward Problem Solution: A Comparative Cortex-Based Analysis

The accuracy of forward models for electroencephalography (EEG) partly depends on head tissues geometry and strongly affects the reliability of the source reconstruction process, but it is not yet clear which brain regions are more sensitive to the choice of different model geometry. In this paper we compare different spherical and realistic head modeling techniques in estimating EEG forward so...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Methods of information in medicine

دوره 39 2  شماره 

صفحات  -