Noninvasive and quantitative intracranial pressure estimation using ultrasonographic measurement of optic nerve sheath diameter
نویسندگان
چکیده
We aimed to quantitatively assess intracranial pressure (ICP) using optic nerve sheath diameter (ONSD) measurements. We recruited 316 neurology patients in whom ultrasonographic ONSD was measured before lumbar puncture. They were randomly divided into a modeling and a test group at a ratio of 7:3. In the modeling group, we conducted univariate and multivariate analyses to assess associations between ICP and ONSD, age, sex, BMI, mean arterial blood pressure, diastolic blood pressure. We derived the mathematical function "Xing &Wang" from the modelling group to predict ICP and evaluated the function in the test group. In the modeling group, ICP was strongly correlated with ONSD (r = 0.758, p < 0.001), and this association was independent of other factors. The mathematical function was ICP = -111.92 + 77.36 × ONSD (Durbin-Watson value = 1.94). In the test group, a significant correlation was found between the observed and predicted ICP (r = 0.76, p < 0.001). Bland-Altman analysis yielded a mean difference between measurements of -0.07 ± 41.55 mmH2O. The intraclass correlation coefficient and its 95%CIs for noninvasive ICP assessments using our prediction model was 0.86 (0.79-0.90). Ultrasonographic ONSD measurements provide a potential noninvasive method to quantify ICP that can be conducted at the bedside.
منابع مشابه
Effect of scuba-diving on optic nerve and sheath diameters
Background :There is not any data available about the effect of high bar pressure condition on intracranial pressure. In this study, the effect of diving on the optic nerve and sheath diameters as non-invasive markers of intracranial pressure has been investigated. Methods : Twenty professional male divers from twenty one volunteers were chosen for this cross-sectional study. Only one perso...
متن کاملPerioperative Noninvasive Assessment of Intracranial Tension by Ultrasonographic Monitoring of Optic Nerve Sheath Diameter: Our Experience
Intracranial hypertension occurs with significant regularity during general anaesthesia. Although majority of times it goes unrecognised and does not cause significant perioperative morbidity, its importance cannot be ignored especially in patients with intracranial pathologies. The intracranial tension can rise significantly during prolonged extreme positioning like steep trendelenburg positio...
متن کاملAssessment of intracranial pressure with ultrasonographic retrobulbar optic nerve sheath diameter measurement
BACKGROUND Ultrasonograpic retrobulbar optic nerve sheath diameter (ONSD) measurement is considered to be an alternative noninvasive method to estimate intracranial pressure,but the further validation is urgently needed. The aim of the current study was to investigate the association of the ultrasonographic ONSD and intracranial pressure (ICP) in patients. METHODS One hundred and ten patients...
متن کاملOptic Nerve Sheath Diameter as a Bedside Assessment for Elevated Intracranial Pressure
A previously fit and healthy 26-year-old lady with no significant medical history presented with a two-month history of headaches. The headaches were prolonged, generalised, and unusually severe for the patient. Examination revealed papilloedema. The patient's optic nerve sheath diameter was measured 3 mm posterior to the globe and found to be 7.5 mm. The patient subsequently had computed tomog...
متن کاملSCIENTIFIC CORRESPONDENCE Measurement of optic nerve sheath diameter by ultrasound: a means of detecting acute raised intracranial pressure in hydrocephalus
Aim: To evaluate the utility of measuring the optic nerve sheath diameter in children with shunted hydrocephalus, suspected of having raised intracranial pressure. Methods: 23 children with shunted hydrocephalus were examined, six had well controlled ICP, 17 however manifested symptoms suggestive of intracranial hypertension. A clinical history was taken from all patients and their parents or c...
متن کامل