Camera Calibration Robust to Defocus Using Phase-Shifting Patterns

نویسندگان

  • Bolin Cai
  • Yuwei Wang
  • Keyi Wang
  • Mengchao Ma
  • Xiangcheng Chen
چکیده

Camera parameters can't be estimated accurately using traditional calibration methods if the camera is substantially defocused. To tackle this problem, an improved approach based on three phase-shifting circular grating (PCG) arrays is proposed in this paper. Rather than encoding the feature points into the intensity, the proposed method encodes the feature points into the phase distribution, which can be recovered precisely using phase-shifting methods. The PCG centers are extracted as feature points, which can be located accurately even if the images are severely blurred. Unlike the previous method which just uses a single circle, the proposed method uses a concentric circle to estimate the PCG center, such that the center can be located precisely. This paper also presents a sorting algorithm for the detected feature points automatically. Experiments with both synthetic and real images were carried out to validate the performance of the method. And the results show that the superiority of PCG arrays compared with the concentric circle array even under severe defocus.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gamma Calibration and Phase Error Compensation for Phase Shifting Profilometry

Phase Shifting Profilometry is a method of structured light whose three-dimensional reconstructions are susceptible to error from Gamma distortion. In practice, the luminance nonlinearity caused by the Gamma distortion effect of a digital video projector and a digital camera yields undesired fringe intensity changes, which substantially reduce the measurement accuracy, and while the effects of ...

متن کامل

A calibration method for non-overlapping cameras based on mirrored phase target

A novel calibration method for non-overlapping cameras is proposed in this paper. A LCD screen is used as a phase target to display two groups of orthogonal phase-shifted sinusoidal patterns during the calibration process. Through a mirror reflection, the phase target is captured by the cameras respectively. The relations between each camera and the phase target can be obtained according the pr...

متن کامل

Full-field calibration and compensation of lateral chromatic aberration based on unwrapped phase

Lateral chromatic aberration (CA) of color cameras has great effects on the imaging quality. This paper presents a novel method to full-field calibrate lateral CA between color channels by using unwrapped phase data. Closed circle sinusoidal fringe patterns having the optimum three-fringe numbers are generated and displayed on a liquid crystal screen consecutively through red, green and blue ch...

متن کامل

A Thin Lens Based Camera Model for Depth Estimation from Defocus and Translation by Zooming

Depth recovery is a central concern in computer vision, and many methods were proposed for the monocular depth estimation by zooming as well as focusing and irising. In the past, there are two distinct approaches in depth by zooming; one is from motion parallax along the optical axis using a pinhole camera model, and the other from defocus using a thin lens camera model. This paper presents a n...

متن کامل

Camera Calibration: Active versus Passive Targets

Traditionally, most camera calibrations rely on a planar target with well-known marks. However, the localization error of the marks in the image is a source of inaccuracy. We propose the use of high-resolution digital displays as active calibration targets to obtain more accurate calibration results for all types of cameras. The display shows a series of coded patterns to generate correspondenc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017