Technetium-99m hexakis 2-methoxy-2-isobutyl isonitrile and thallium-201 extraction, washout, and retention at varying coronary flow rates in rabbit heart.
نویسندگان
چکیده
Technetium-99m hexakis 2-methoxy-2-isobutyl isonitrile (Tc-MIBI) and thallium-201 extraction, washout, and retention were investigated and compared in 20 isolated, isovolumic, retrograde blood-perfused rabbit hearts at flow rates ranging from 0.5 to 3.5 ml/g wet wt min-1 in the absence of tracer recirculation. Mean Tc-MIBI peak instantaneous extraction was lower (0.55 +/- 0.10, p less than 0.001) and more affected by flow rate (p less than 0.05) than 201Tl peak instantaneous extraction (0.83 +/- 0.06). In contrast, the rate of 201Tl washout was significantly faster (p less than 0.05) and initially more dependent on perfusion rate (p less than 0.05) than Tc-MIBI washout. Reflecting its higher peak instantaneous extraction, 201Tl retention was 55-79% higher immediately after isotope injection (p less than 0.001) than Tc-MIBI retention, and relative changes in maximal 201Tl net uptake correlated better (p less than 0.05) with relative flow changes than maximal Tc-MIBI net uptake. However, due to its faster washout rate, the superiority of thallium over Tc-MIBI as a perfusion indicator was lost within 10 minutes of tracer injection under the present single-pass experimental conditions. These data were interpreted to indicate that 1) Tc-MIBI is not as well extracted and has a slower washout rate than 201Tl; 2) varying the coronary flow rate has significant but divergent effects on the extraction, washout, and retention of Tc-MIBI and 201Tl; and 3) the present results support continued evaluation of Tc-MIBI as a possible perfusion indicator.
منابع مشابه
LABORATORY INVESTIGATION NUCLEAR CARDIOLOGY Myocardial kinetics of technetium-99m-hexakis-2- methoxy-2-methylpropyl-isonitrile
To study the potential usefulness of technetium-99m hexakis-2-methoxy-2-methylpropyl-isonitrile (Tc-MIBI) as a cardiac perfusion imaging agent, the left circumflex coronary arteries of 12 dogs were partially occluded. Eight additional control dogs had no coronary artery stenosis. Myocardial Tc-MIBI activities in the left circumflex and left anterior descending zones were continuously monitored ...
متن کاملComparison of the myocardial uptake of a technetium-labeled isonitrile analogue and thallium.
The myocardial transmicrovascular transport of thallium-201 (201Tl) and technetium-99m hexakis(2-methoxyisobutylisonitrile) (MIBI) were compared during variable blood flow levels in nine blood-perfused, isolated rabbit hearts. Seventeen injections of radiolabeled albumin and EDTA as well as 201Tl and MIBI were performed by indicator-dilution techniques. When coronary flow was varied from 0.52 t...
متن کاملComparison of technetium-99m sestamibi and thallium-201 retention characteristics in canine myocardium.
OBJECTIVES The aim of this study was to compare the myocardial retention of technetium-99m (Tc-99m) sestamibi and thallium-201 over a wide range of blood flow at different time points after tracer injection. BACKGROUND Technetium-99m sestamibi has been proposed as a new perfusion tracer with better physical characteristics than those of thallium-201 for scintigraphic imaging. However, no stud...
متن کاملMyocardial kinetics of technetium-99m-hexakis-2-methoxy-2-methylpropyl-isonitrile.
To study the potential usefulness of technetium-99m hexakis-2-methoxy-2-methylpropyl-isonitrile (Tc-MIBI) as a cardiac perfusion imaging agent, the left circumflex coronary arteries of 12 dogs were partially occluded. Eight additional control dogs had no coronary artery stenosis. Myocardial Tc-MIBI activities in the left circumflex and left anterior descending zones were continuously monitored ...
متن کاملMechanism for abnormal thallium-201 myocardial scintigraphy in patients with left bundle branch block in the absence of angiographic coronary artery disease.
Patients with left bundle branch block (LBBB) often show abnormal images on exercise thallium (T1)-201 scintigraphy without evidence of significant coronary stenosis. We investigated the mechanism for this phenomenon. Six patients with LBBB and without significant coronary stenosis underwent T1-201 SPECT, ECG-gated SPECT imaging with Tc-99m-methoxyisobutyl-isonitrile (MIBI), and atrial pacing s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 82 3 شماره
صفحات -
تاریخ انتشار 1990