Comparison of 99mTc-sestamibi and 11C-methionine PET/CT in the localization of parathyroid adenomas in primary hyperparathyroidism.
نویسندگان
چکیده
AIM To evaluate the usefulness of (11)C-methionine PET/CT (MET) in the localization of the parathyroid adenomas and to compare the results with those obtained with the conventional technique in double-phase (99m)Tc-sestamibi scintigraphy (MIBI). We evaluated the optimal timing to acquire MET images. MATERIAL AND METHODS A prospective study that included 14 patients (mean age: 65.5 ± 9.7 years) with primary hyperparathyroidism (PH) who underwent surgery was performed. Mean serum iPTH was 215.8 ± 108 pg/mL and serum calcium 10.8 ± 0.9 mg/dL. MIBI (planar and SPECT) was obtained 10 min and 2-3h after injection of 740 MBq (20 mCi) of (99m)Tc-sestamibi. MET was obtained 10 min and 40 min after injection of 740 MBq (20 mCi) of (11)C-methionine. MIBI and MET images were visually evaluated and compared. A score for 10 min and 40 min MET images from 0 (no abnormal uptake) to 3 (intense uptake) was assigned. RESULTS MIBI and MET were positive and concordant in 11/14 patients and in 10 of them the parathyroid adenoma was correctly localized. In 3/14 MIBI was positive and MET negative (MIBI correctly localized the parathyroid adenoma in 2 of them). According to the timing of MET imaging acquisition, the 10 min and 40 min acquisition showed the same score in 10 patients, it was higher at 10 min acquisition in 3 and in 1 the parathyroid adenoma was only detected at 40 min acquisition. CONCLUSION MIBI remains the technique of choice for the localization of parathyroid adenomas in patients with PH. MET may play a complementary role in selected patients. Delayed acquisition should be included in the MET protocol when the early acquisition is negative.
منابع مشابه
SPECT-CT fusion in the diagnosis of hyperparathyroidism
Objective(s): In this study, we aimed to analyze the relationship between the diagnostic ability of fused single photon emission computed tomography/computed tomography (SPECT/CT) images in localization of parathyroid lesions and the size of adenomas or hyperplastic glands. Methods: Five patients with primary hyperparathyroidism (PHPT) and 4 patients with secondary hyperparathyroidism (SHPT) we...
متن کاملPlanar scintigraphy with 123I/99mTc-sestamibi, 99mTc-sestamibi SPECT/CT, 11C-methionine PET/CT, or selective venous sampling before reoperation of primary hyperparathyroidism?
UNLABELLED All patients with primary hyperparathyroidism should undergo localization studies before reoperation, but it is not known which method is most accurate. The purpose of this prospective study was to compare the performance of planar scintigraphy with (123)I/(99m)Tc-sestamibi, (99m)Tc-sestamibi SPECT (SPECT/CT), (11)C-methionine PET/CT, and selective venous sampling (SVS) in persistent...
متن کاملAbsent radiotracer uptake in thyroid gland in parathyroid scintigraphy with 99mTc-MIBI: A case report
Localization of 99mTc- hexakis-2-methoxyisobutylisonitrile (99mTc-MIBI) by parathyroid adenomas is well known, and this warrants MIBI scan to evaluate suspected parathyroid adenoma in primary hyperparathyroidism. Typically, the radionuclide concentrates in both the thyroid gland and parathyroid adenoma in early images, and later on delayed images washes out slowly from the...
متن کاملUtility of 99mTc-Sestamibi SPECT/CT in the Early Localization of Metastatic Parathyroid Carcinoma
Parathyroid carcinoma is very rare, with only a few documented cases. Hence, metastatic lesions are infrequently documented on scintigraphic imaging. We present a case of a 63-year-old female presenting with elevated serum levels of ionized calcium and parathyroid hormone (PTH) who was referred to our department for a parathyroid scan with SPECT/ CT. Parathyroid scintigraphy showed a focus of i...
متن کاملParathyroid adenoma Localization
Background: Bilateral neck exploration is the gold standard for parathyroid adenoma localization in primary hyperparathyroidism. But surgeons do not have adequate experience for accurate surgical exploration and new methods are developed for surgery like unilateral exploration and minimally invasive surgery, thus, preoperative localization could reduces time and stress in surgical performance....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Revista espanola de medicina nuclear e imagen molecular
دوره 33 2 شماره
صفحات -
تاریخ انتشار 2014