Transcatheter aortic valve implantation using anatomically oriented, marrow stromal cell-based, stented, tissue-engineered heart valves: technical considerations and implications for translational cell-based heart valve concepts.
نویسندگان
چکیده
OBJECTIVES While transcatheter aortic valve implantation (TAVI) has rapidly evolved for the treatment of aortic valve disease, the currently used bioprostheses are prone to continuous calcific degeneration. Thus, autologous, cell-based, living, tissue-engineered heart valves (TEHVs) with regeneration potential have been suggested to overcome these limitations. We investigate the technical feasibility of combining the concept of TEHV with transapical implantation technology using a state-of-the-art transcatheter delivery system facilitating the exact anatomical position in the systemic circulation. METHODS Trileaflet TEHVs fabricated from biodegradable synthetic scaffolds were sewn onto self-expanding Nitinol stents seeded with autologous marrow stromal cells, crimped and transapically delivered into the orthotopic aortic valve position of adult sheep (n = 4) using the JenaValve transapical TAVI System (JenaValve, Munich, Germany). Delivery, positioning and functionality were assessed by angiography and echocardiography before the TEHV underwent post-mortem gross examination. For three-dimensional reconstruction of the stent position of the anatomically oriented system, a computed tomography analysis was performed post-mortem. RESULTS Anatomically oriented, transapical delivery of marrow stromal cell-based TEHV into the orthotopic aortic valve position was successful in all animals (n = 4), with a duration from cell harvest to TEHV implantation of 101 ± 6 min. Fluoroscopy and echocardiography displayed sufficient positioning, thereby entirely excluding the native leaflets. There were no signs of coronary obstruction. All TEHV tolerated the loading pressure of the systemic circulation and no acute ruptures occurred. Animals displayed intact and mobile leaflets with an adequate functionality. The mean transvalvular gradient was 7.8 ± 0.9 mmHg, and the mean effective orifice area was 1.73 ± 0.02 cm(2). Paravalvular leakage was present in two animals, and central aortic regurgitation due to a single-leaflet prolapse was detected in two, which was primarily related to the leaflet design. No stent dislocation, migration or affection of the mitral valve was observed. CONCLUSIONS For the first time, we demonstrate the technical feasibility of a transapical TEHV delivery into the aortic valve position using a commercially available and clinically applied transapical implantation system that allows for exact anatomical positioning. Our data indicate that the combination of TEHV and a state-of-the-art transapical delivery system is feasible, representing an important step towards translational, transcatheter-based TEHV concepts.
منابع مشابه
Tissue-engineered heart valve with a tubular leaflet design for minimally invasive transcatheter implantation.
Transcatheter aortic valve implantation of (nonviable) bioprosthetic valves has been proven a valid alternative to conventional surgical implantation in patients at high or prohibitive mortality risk. In this study we present the in vitro proof-of-principle of a newly developed tissue-engineered heart valve for minimally invasive implantation, with the ultimate aim of adding the unique advantag...
متن کاملTrans-catheter Bioprosthetic Heart Valve Implantation in Iran (Tehran Heart Centre Experience)
Introduction: With the development of interventional cardiology in the world, in addition to coronary and aortic diseases, the treatment of heart valve diseases through catheters has recently begun. The treatment of aortic stenosis (which was only possible with open surgery and valve replacement) was first performed in the world in 2002 by Alain Cribier in France with catheter insertion of the ...
متن کاملComparison of Clinical Outcomes Seprate and semi continus sewing methods during and after Heart valves Surgery
Background and Aims: Various therapies and surgeries are applied in heart valve surgery, including interrupted and semi-continuous suture techniques. Therefore, this study aimed to compare the clinical implications of two methods of interrupted and semi-continuous suture techniques during and after mitral or aortic valve replacement surgery among patients referred to Department of Surgery, Scho...
متن کاملStented bioprostheses in aortic position
INTRODUCTION Biological stented prostheses are currently the main type of prosthetic valve used for aortic valve replacement. The ratio of bioprotheses to mechanical prostheses has switched in the last 15 years; the percentage of biological prostheses implanted has risen from 30 % to 85 %. Moreover the total number of implanted stented bioprostheses remained stable over the last years despite ...
متن کاملInjectable Tissue-Engineered Pulmonary Heart Valve Implantation Into the Pig Model: A Feasibility Study
BACKROUND Transcatheter pulmonary valve replacement is currently performed in clinical trials, however limited by the use of glutaraldehyde treated bioprostheses. This feasibility study was performed to evaluate delivery-related tissue distortion during implantation of a tissue engineered (TE) heart valves. MATERIAL AND METHOD The injectable TE heart valve was mounted on a self-expanding niti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 45 1 شماره
صفحات -
تاریخ انتشار 2014