The accuracy of pulse oximetry in emergency department patients with severe sepsis and septic shock: a retrospective cohort study

نویسندگان

  • Ben J Wilson
  • Hamish J Cowan
  • Jason A Lord
  • Dan J Zuege
  • David A Zygun
چکیده

BACKGROUND Pulse oximetry is routinely used to continuously and noninvasively monitor arterial oxygen saturation (SaO2) in critically ill patients. Although pulse oximeter oxygen saturation (SpO2) has been studied in several patient populations, including the critically ill, its accuracy has never been studied in emergency department (ED) patients with severe sepsis and septic shock. Sepsis results in characteristic microcirculatory derangements that could theoretically affect pulse oximeter accuracy. The purposes of the present study were twofold: 1) to determine the accuracy of pulse oximetry relative to SaO2 obtained from ABG in ED patients with severe sepsis and septic shock, and 2) to assess the impact of specific physiologic factors on this accuracy. METHODS This analysis consisted of a retrospective cohort of 88 consecutive ED patients with severe sepsis who had a simultaneous arterial blood gas and an SpO2 value recorded. Adult ICU patients that were admitted from any Calgary Health Region adult ED with a pre-specified, sepsis-related admission diagnosis between October 1, 2005 and September 30, 2006, were identified. Accuracy (SpO2 - SaO2) was analyzed by the method of Bland and Altman. The effects of hypoxemia, acidosis, hyperlactatemia, anemia, and the use of vasoactive drugs on bias were determined. RESULTS The cohort consisted of 88 subjects, with a mean age of 57 years (19 - 89). The mean difference (SpO2 - SaO2) was 2.75% and the standard deviation of the differences was 3.1%. Subgroup analysis demonstrated that hypoxemia (SaO2 < 90) significantly affected pulse oximeter accuracy. The mean difference was 4.9% in hypoxemic patients and 1.89% in non-hypoxemic patients (p < 0.004). In 50% (11/22) of cases in which SpO2 was in the 90-93% range the SaO2 was <90%. Though pulse oximeter accuracy was not affected by acidoisis, hyperlactatementa, anemia or vasoactive drugs, these factors worsened precision. CONCLUSIONS Pulse oximetry overestimates ABG-determined SaO2 by a mean of 2.75% in emergency department patients with severe sepsis and septic shock. This overestimation is exacerbated by the presence of hypoxemia. When SaO2 needs to be determined with a high degree of accuracy arterial blood gases are recommended.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی موارد سپسیس و شوک سپتیک در بخش مراقبت های ویژه بیمارستان مرکز طبی کودکان

Sepsis is the systemic response to severe infection in critically ill patients. Sepsis, septic syndrome & septic shock represent the increasingly severe stages of the same disease. Despite the remarkable improvements in outcome, sepsis & septic shock remain an important cause of morbidity & mortality in children. This is a retrospective study among the patients who were admitted in the pediatri...

متن کامل

Prospective evaluation of an automated method to identify patients with severe sepsis or septic shock in the emergency department

BACKGROUND Sepsis is an often-fatal syndrome resulting from severe infection. Rapid identification and treatment are critical for septic patients. We therefore developed a probabilistic model to identify septic patients in the emergency department (ED). We aimed to produce a model that identifies 80 % of sepsis patients, with no more than 15 false positive alerts per day, within one hour of ED ...

متن کامل

The impact of organizational characteristics on the outcomes of septic patients admitted to the ICU.

Methods Retrospective cohort study in 6,779 patients with severe sepsis (n = 5,294, 78%) or septic shock (n = 1,485, 22%) directly admitted from the emergency department to 69 ICUs (private hospitals, n= 62(90%); medical-surgical; n= 57(83%)) during 2013. We retrieved demographic, clinical and outcome data from an electronic ICU quality registry (Epimed Monitor System). We surveyed ICUs using a...

متن کامل

The effect of physiologic dose of intravenous hydrocortisone in patients with refractory septic shock: a randomized control trial

Objective: Septic shock is a response to infection and tissue hypoperfusion which does not respond to fluid therapy and eventually leads to organ dysfunction. Aggressive treatment of a broad-spectrum antimicrobial and supportive measures are the cornerstones of successful treatment. In addition to the main treatment, there are adjunctive therapies. Steroids are one of the treat...

متن کامل

Severe sepsis in community-acquired pneumonia: when does it happen, and do systemic inflammatory response syndrome criteria help predict course?

STUDY OBJECTIVES Most natural history studies of severe sepsis are limited to ICU populations. We describe the onset and timing of severe sepsis during the hospital course for patients hospitalized with community-acquired pneumonia (CAP). We also determine the ability of the systemic inflammatory response syndrome (SIRS) and other proposed risk stratification scores measured at emergency depart...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2010