Corrosion Behavior of Solution- Annealed CoCrMo Medical Implant Alloys
نویسندگان
چکیده
Corrosion behavior of solution annealed high-carbon and low-carbon CoCrMo wrought alloy, commonly used in medical joint implants, was investigated. The surface passivation properties remained similar with and without the various solution anneal conditions, while the rate of corrosion was lower for solution annealed high-carbon CoCrMo. Corrosion was found to target phase boundaries and certain grain boundaries in the high-carbon alloy. This preferential corrosion may be due to chromium depletion at the boundaries, higher grain boundary energy as a function of the misorientation angle between the neighboring grains, or both. These findings suggest that solution annealing the high-carbon CoCrMo alloys may lower the implant’s rate of corrosion in vivo due to the more corrosion-resistant microstructure.
منابع مشابه
Intergranular pitting corrosion of CoCrMo biomedical implant alloy.
CoCrMo samples of varying microstructure and carbon content were electrochemically corroded in vitro and examined by scanning electron microscopy and electron backscatter diffraction techniques. The rate of corrosion was minimized (80% reduction from icorr = 1396 nA/cm(2) to icorr = 276 nA/cm(2) ) in high-carbon CoCrMo alloys which displayed a coarser grain structure and partially dissolved sec...
متن کاملThe electrochemical and mechanical behavior of passivated and TiN/AlN-coated CoCrMo and Ti6Al4V alloys.
The mechanical and electrochemical behavior of the surface oxides of CoCrMo and Ti6Al4V alloys during fracture and repassivation play an important role in the corrosion of the taper interfaces of modular hip implants. This behavior was investigated in one group of CoCrMo and Ti6Al4V alloy samples passivated with nitric acid and another group coated with a novel TiN/AlN coating. The effects of m...
متن کاملWear of CoCrMo alloys used in metal-on-metal hip joints A tribocorrosion appraisal
A good biocompatibility, excellent mechanical properties and high corrosion resistance characterize CoCrMo alloys. Therefore they are widely used for artificial joints in biomedical implants. However, the degradation of the implants during service life leads to the release into the body of toxic ions and wear particles. This continuous degradation is of concern for long-term stability of the im...
متن کاملTribocorrosion of Pulsed Plasma-Nitrided CoCrMo Implant Alloy
In the present study, a forged CoCrMo (ISO 5832-12) has been subjected to pulsed plasma treatment in a N2/H2 atmosphere at low temperatures (below 500 C). This treatment resulted in the formation of a layer composed by dispersed chromium nitride particles in a N-enriched metal matrix. The materials were tested for corrosion and tribocorrosion performance in 0.9 wt% NaCl at room temperature unde...
متن کاملInfluence of the sliding velocity and the applied potential on the corrosion and wear behavior of HC CoCrMo biomedical alloy in simulated body fluids.
The corrosion and tribocorrosion behavior of an as-cast high carbon CoCrMo alloy immersed in phosphate buffered solution (PBS) and phosphate buffered solution with bovine serum albumin (PBS+BSA) have been analyzed by electrochemical techniques and surface microscopy. After the electrochemical characterization of the alloy in both solutions, the sample was studied tribo-electrochemically (by ope...
متن کامل