Indoor air quality investigation on commercial aircraft.

نویسندگان

  • S C Lee
  • C S Poon
  • X D Li
  • F Luk
چکیده

Sixteen flights had been investigated for indoor air quality (IAQ) on Cathay Pacific aircraft from June 1996 to August 1997. In general, the air quality on Cathay Pacific aircraft was within relevant air quality standards because the average age of aircraft was less than 2 years. Carbon dioxide (CO2) levels on all flights measured were below the Federal Aviation Administration (FAA) standard (30,000 ppm). The CO2 level was substantially higher during boarding and de-boarding than cruise due to low fresh air supply. Humidity on the aircraft was low, especially for long-haul flights. Minimum humidity during cruise was below the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) minimum humidity standard (20%). The average temperature was within a comfortable temperature range of 23 +/- 2 degrees C. The vertical temperature profile on aircraft was uniform and below the International Standard Organization (ISO) standard. Carbon monoxide levels were below the FAA standard (50 ppm). Trace amount of ozone detected ranged from undetectable to 90 ppb, which was below the FAA standard. Particulate level was low for most non-smoking flights, but peaks were observed during boarding and de-boarding. The average particulate level in smoking flights (138 micrograms/m3) was higher than non-smoking flights (7.6 micrograms/m3). The impact on IAQ by switching from low-mode to high-mode ventilation showed a reduction in CO2 levels, temperature, and relative humidity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental studies of thermal environment and contaminant transport in a commercial aircraft cabin with gaspers on.

Gaspers installed in commercial airliner cabins are used to improve passengers' thermal comfort. To understand the impact of gasper airflow on the air quality in a cabin, this investigation measured the distributions of air velocity, air temperature, and gaseous contaminant concentration in five rows of the economy-class section of an MD-82 commercial aircraft. The gaseous contaminant was simul...

متن کامل

Measurements of Indoor Air Quality on Commercial Transport Aircraft

Exposures to cabin environmental contaminants were measured on 36 commercial transport aircraft. The objectives were to characterize levels of contaminants and evaluate the relationship between flight factors such as aircraft size, occupancy, ventilation, and flight length, and environmental parameters. Monitoring was conducted at two coach locations for the duration of the flight for VOCs, nit...

متن کامل

Novel air distribution systems for commercial aircraft cabins

Air distribution systems in commercial aircraft cabins are important for providing a healthy and comfortable environment for passengers and crew. The mixing air distribution systems used in existing aircraft cabins create a uniform air temperature distribution and dilute contaminants in the cabins. The mixing air distribution systems could spread infectious airborne diseases. To improve the air...

متن کامل

Simulation Modeling and Analysis of In-Flight Service Operations for Commercial Passenger Flights

Nowadays, in-flight comfort has become an essential characteristic to survive in domestic airline businesses. Air hostesses’ quality of service and response time to customer demand plays a vital role in enhancing quality of the flight experience and passenger satisfaction. However, additional requirements on air hostess expose them to fatigue which could eventually result in job dissatisfac...

متن کامل

An Assessment of Indoor Air Quality and Thermal Comfort in Educational Spaces (Case Study: Girls' High Schools in Arak, Iran)

As s‌tudents spend one-third of their time at school, their health, comfort, and productivity are mos‌tly influenced by thermal condition and indoor air quality of classrooms. Regarding that manual window-opening is a common way for providing fresh air in classes and s‌tudents aren't allowed to change their uniform, position or control the windows during the lesson hours, providing thermal comf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Indoor air

دوره 9 3  شماره 

صفحات  -

تاریخ انتشار 1999