Different refractive status demonstrated different accommodative stamina under natural binocular near viewing condition
نویسندگان
چکیده
The emmetropes and myopes were reported to have different monocular accommodative stamina at distance, but not at near. The purpose of this study was to further investigate the binocular accommodative stamina under natural binocular viewing condition. Methods: Accommodative stamina of 40 young university students was investigated over one-minute duration with a ±2.00 D lens flipper at 40 cm. The measurement was done binocularly to ensure the natural interaction between accommodation and vergence. The data collection was recorded as cycle per minute (cpm). Results: There was a significant difference [t= -2.75, p = 0.01] in the near natural binocular accommodative stamina between emmetropes (mean = 7.90 cpm) and myopes (mean = 10.95 cpm). Discussion: The myopes demonstrated higher cyclic rate of accommodative stamina compared to emmetropes at near. These findings suggested that the ability to clear near optical blur might be different between emmetropes and myopes.
منابع مشابه
Clinical exhibition of increased accommodative loads for binocular fusion in patients with basic intermittent exotropia
BACKGROUND To investigate the accommodative loads change needed to maintain binocular fusion in patients with intermittent exotropia (IXT). METHODS Seventeen consecutive patients with basic IXT and 15 normal controls were recruited. The WAM-5500 autorefractor (GrandSeiko, Fukuyama, Japan) was used to measure refractive error (D) under binocular and monocular viewing conditions at 6 m, 50 cm, ...
متن کاملStereoacuity at distance and near.
PURPOSE Because previous studies have reported conflicting evidence, we examined a possible difference in stereoacuity between distance and near, in particular using a random-dot display. We compared distance and near stereoacuities using identical presentation formats at the two distances. METHODS Twelve young adults with low, stable refractive errors and apparently normal binocular vision p...
متن کاملLens induced aniso-accommodation
Despite the evidence for consensual accommodation in response to consensual accommodative stimuli, only a few studies have investigated the binocular accommodative response to unequal (aniso) accommodative stimuli. Past studies investigating an unequal binocular accommodative response (aniso-accommodation) to aniso-accommodative stimuli have been limited by viewing conditions and measurement te...
متن کاملDynamics of the near response under natural viewing conditions with an open-view sensor.
We have studied the temporal dynamics of the near response (accommodation, convergence and pupil constriction) in healthy subjects when accommodation was performed under natural binocular and monocular viewing conditions. A binocular open-view multi-sensor based on an invisible infrared Hartmann-Shack sensor was used for non-invasive measurements of both eyes simultaneously in real time at 25Hz...
متن کاملEffect of Illumination on Ocular Status Modifications Induced by Short-Term 3D TV Viewing
Objectives. This study aimed to compare changes in ocular status after 3D TV viewing under three modes of illumination and thereby identify optimal illumination for 3D TV viewing. Methods. The following measures of ocular status were assessed: the accommodative response, accommodative microfluctuation, accommodative facility, relative accommodation, gradient accommodative convergence/accommodat...
متن کامل