Study on Very Fast Transient Overvoltage of Closing No-load China UHV Transmission Demonstration Project Jindongnan-Nanyang- Jingmen 1000 kV Transmission Lines

نویسندگان

  • Bo Ye
  • Ming Li
  • Biao Bai
  • Gefei Qiu
چکیده

When the ultra high voltage (UHV) substation used the gas insulated switchgear (GIS) system to switch lines with capacitive current, the pre-breakdown and multiple reignition will occur between switching contacts. Because of discharge characteristics of SF6 and special structures of GIS system, the variations of the electromagnetic transient process and very fast transient overvoltage (VFTO) are very fast and extremely complex. The development process and characteristics of VFTO remain to be dealt with to seek effective suppression measures. The overvoltage of closing no-load long lines on GIS system is analyzed in detail. The simulation model of the very fast transient process of closing no-load long lines on UHV GIS system is established. The VFTO of closing no-load China UHV transmission demonstration project Jindongnan-Nanyang-Jingmen 1000 kV transmission lines is analyzed using electromagnetic transient simulation software ATP-EMTP. The VFTO of closing no-load long lines on UHV GIS system is simulated and calculated, when the system has no additional closing resistors and lightning arresters, additional single stage closing resistors, additional multistage closing resistors, lightning arresters in two terminals of lines, lightning arresters in two terminals and the middle of lines, and additional multistage closing resistors and lightning arresters in two terminals and the middle of lines. The simulation results show that the additional multistage closing resistors and lightning arresters in two terminals and the middle of lines can effectively restrain the VFTO of closing no-load long lines on UHV GIS system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of New Weighted Controlled Switching Overvoltage by RBFN Model

Mitigating switching overvoltages (SOVs) and conducting well-suited insulation coordination for handling stresses are very important in UHV transmission Lines. The best strategy in the absence of arresters is controlled switching (CS). Although elaborate works on electromagnetic transients are considered in the process of designing transmission systems, such works are not prevalent in day-to-da...

متن کامل

System Aspects of 1100kV AC Transmission Technologies in Japan: Solutions for Network Problems Specific to UHV AC Transmission System and Insulation Coordination

For development of a UHV transmission system, sophisticated system design is indispensable to deal with increased charging MVA and higher transmission voltage. Furthermore, for realization of technical and economical optimization throughout the design of the transmission line and the substation, solutions for network problems specific to UHV AC transmission system and problems with insulation c...

متن کامل

Attenuation and deformation characteristics of lightning impulse corona traveling along bundled transmission lines

Comprehensive study of the impulse corona characteristics is helpful to understand the transient process and guarantee a suitable insulation design of power transmission systems. In this paper, first the attenuation and deformation characteristics of lightning overvoltage traveling along a 500 kV experimental transmission line are tested. Then the lightning impulse corona characteristics on dif...

متن کامل

Back-flashover Investigation of HV Transmission Lines Using Transient Modeling of the Grounding Systems

The article presents the transients analysis of the substation grounding systems and transmission line tower footing resistances which can affect to the back-flashover (BF) or overvoltage across insulator chain in an HV power systems by using EMTP-RV software. The related transient modeling of the grounding systems is based on a transmission line (TL) model with considering the soil ionization....

متن کامل

Technology and Development of 800 kV HVDC Applications

Bulk Power HVDC transmission schemes over distances of up to 2000 km are currently under planning for various large hydropower stations in India and China. Ultra high dc voltage (UHVDC) up to 800 kV is the preferred dc voltage level for these applications. Currently world-wide existing HVDC schemes are limited to maximum voltage levels of 500 kV to 600 kV. Therefore, the impact of increased ste...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014