Measuring tooth movement in 3D Resolution, accuracy and reliability of the optical motion capture system

نویسنده

  • H. Liu
چکیده

This paper presents the development of a novel application using motion analysis techniques to measure tooth movement in 3D. Measuring the relative displacements of teeth under load allows a greater understanding of the mechanical properties of the periodontal ligament (PDL). Two marker clusters were fixed onto the measured tooth and the reference tooth via orthodontic brackets and movements were captured using two 60 Hz infrared cameras. Software was modified to calculate 3D tooth displacements and rotations. The development of this system will provide reliable data for modelling the periodontal ligament (PDL). It is therefore important to evaluate the measurement system characteristics. • System accuracy, defined as % max. absolute error / measurement range, was 2.13 % using spherical markers and 1.5 % using diamond markers for a measurment range of 20-200μm. • System resolution, defined as minimum step size that the system could accurately detect, was 10μm. • System noise band was 5.76μm • System repeatability, defined as max. st. dev. in the measurement range, was measured in the x, y and z directions on different days (light intensity and temperature), five times, using step up and then step down measurements for the same step size and was range from ± 1.7μm to ± 3.9μm. These results demonstrate that the system is sufficiently accurate to measure tooth displacements (120160 μm) and could potentially be useful in many other applications. Keywords-component; tooth movement, system accuracy

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy map of an optical motion capture system with 42 or 21 cameras in a large measurement volume.

Optical motion capture is commonly used in biomechanics to measure human kinematics. However, no studies have yet examined the accuracy of optical motion capture in a large capture volume (>100m3), or how accuracy varies from the center to the extreme edges of the capture volume. This study measured the dynamic 3D errors of an optical motion capture system composed of 42 OptiTrack Prime 41 came...

متن کامل

Design and Manipulation 3D Imaging System by using Photodiode Grid

Introduction: Radiation imaging is one of the applicable methods in diagnostic medicine and nondestructive testing for industrial applications. In nondestructive 3D imaging, in addition to the radiation source, there is a requirement for a suitable detection system, data acquisition system, mechanical sections for moving objects, reconstruction algorithm and finally a computer for processing an...

متن کامل

Measuring Spinal Mobility in Ankylosing Spondylitis: Comparison of Motion Capture Results against Conventional Metrology and Radiological Scores

Ankylosing spondylitis (AS) is a chronic rheumatic disease than affects mainly to the spine reducing its mobility. Spinal mobility restrictions are the measures most commonly used in AS but rheumatologist use basic tools as tapes and goniometers. They also use certain indexes (for example BASMI) that group several measurements. Some studies show lack of reliability, accuracy and responsiveness ...

متن کامل

بررسی مقایسه‌ای دو سیستم Cone Beam CT به لحاظ دقت اندازه‌گیری خطی محل‌های قراردهی ایمپلنت در مندیبل به‌صورت In Vitro

Background and Objective: There are critical areas in the mandible that should be considered during implant placement such as inferior alveolar canal, mental foramen, and the root of the adjacent tooth. Two-dimensional images obtained from periapical, panoramic, and conventional tomography are considered in the evaluation of implant placement and bone quality. Cone-beam computed tomography (CBC...

متن کامل

Development of an Advanced Optical Coherence Tomography System for Radiation Dosimetry

Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006