The Calibration of a Parallel Manipulator with Binary Actuation
نویسندگان
چکیده
This paper investigates how parameter identification can improve the calibration of elastically averaged parallel manipulators. The method developed is applied to a needle manipulator for intra-Magnetic Resonance Imaging (MRI) prostate cancer treatment. The device uses MRI-compatible Dielectric Elastomer Actuators to precisely guide a needle during its insertion for taking biopsy or implanting radioactive seeds in the prostate. Here, an analytical model of the device is presented and a sensitivity analysis identifies the key model parameters. Parameter identification is conducted with an optimization algorithm. The method is tested on both simulated parameter values and experimental data. The results show that the method can improve the device accuracy by at least one order of magnitude (on simulated parameters).
منابع مشابه
Experimental Calibration of the Constraining Linkage of a 4 Degrees of Freedom Parallel Manipulator
In this article, an experimental calibration of the constraining linkage of a wire-actuated parallel robot is discussed. The experimental test bed includes a prototyped 4 degrees of freedom wire-actuated parallel manipulator and an optical tracking system. The parallel manipulator employs hybrid actuation ofjoints and wires and includes a rigid branch to constrain the motion of its mobile platf...
متن کامل3-RPS Parallel Manipulator Dynamical Modelling and Control Based on SMC and FL Methods
In this paper, a dynamical model-based SMC (Sliding Mode Control) is proposed fortrajectory tracking of a 3-RPS (Revolute, Prismatic, Spherical) parallel manipulator. With ignoring smallinertial effects of all legs and joints compared with those of the end-effector of 3-RPS, the dynamical model ofthe manipulator is developed based on Lagrange method. By removing the unknown Lagrange multipliers...
متن کاملForward Position Kinematics of a Parallel Manipulator with New Architecture
The forward position kinematics (FPK) of a parallel manipulator with new architecture supposed to be used as a moving mechanism in a flight simulator project is discussed in this paper. The closed form solution for the FPK problem of the manipulator is first determined. It has, then, been shown that there are at most 24 solutions for FPK problem. This result has been verified by using other tec...
متن کاملA structure design method for compliant parallel manipulators with actuation isolation
Since precise linear actuators of a compliant parallel manipulator suffer from their inability to tolerate the transverse motion/load in the multi-axis motion, actuation isolation should be considered in the compliant manipulator design to eliminate the transverse motion at the point of actuation. This paper presents an effective design method for constructing compliant parallel manipulators wi...
متن کاملRobust nonlinear control of a planar 2-DOF parallel manipulator with redundant actuation
A new robust nonlinear controller is presented and applied to a planar 2-DOF parallel manipulator with redundant actuation. The robust nonlinear controller is designed by combining the nonlinear PD (NPD) control with the robust dynamics compensation. The NPD control is used to eliminate the trajectory disturbances, unmodeled dynamics and nonlinear friction, and the robust control is used to res...
متن کامل