Comparison of Two Autonomous AC-DC Converters for Piezoelectric Energy Scavenging Systems

نویسندگان

  • Enrico Dallago
  • Daniele Miatton
  • Giuseppe Venchi
  • Valeria Bottarel
  • Giovanni Frattini
  • Giulio Ricotti
  • Monica Schipani
چکیده

Piezoelectric Energy Scavenging Systems (PESS) are used to convert the energy of mechanical vibrations into electrical energy exploiting the piezoelectric effect. Their output is a voltage which strongly varies in time; to obtain a suitable supply source an AC-DC conversion of the output voltage of these transducers is needed. Since the output power level of the energy transducer can be very low, the conversion should be as efficient as possible. The paper describes an active AC-DC converter, based on the voltage doubler topology, in which two different driving circuitries have been implemented. The proposed solutions are fully autonomous, i.e. they are supplied by the energy that they harvest. To reduce and to optimize their power consumption a bias circuit has been designed to make the total bias current supply independent. A test chip has been diffused using STMicroelectronics 5V CMOS technology. The performances of the two solutions were compared with the ones of a passive Schottky based voltage doubler. The figures of merit were the average power supplied by the piezoelectric transducer and the average power delivered on a load resistance. Furthermore, the significance of such parameters is also discussed, and a more general figure of merit is defined with the advantage of also weighting the ability of the converter to harvest all the power available at the transducer terminals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Distributed Control Architecture for Autonomous Operation of a Hybrid AC/DC Microgrid System

Hybrid AC/DC microgrids facilitate the procedure of DC power connection into the conventional AC power system by developing the distributed generations (DGs) technologies. The conversion processes between AC and DC electrical powers are more convenient by hybrid systems. In this paper, an energy management system (EMS) for a hybrid microgrid network is proposed due to the optimal utilization of...

متن کامل

DC Microgrid Protection in the Presence of the Photovoltaic and Energy Storage Systems

In recent years, most of the loads and distributed generations are connected to the AC grid through the power electronic converters. Using the DC grid beside the AC grid can reduce the conversion stages and power losses. Protection of the DC grids is a challenging issue because of the new structures of DC grids and fast transients of the DC faults. This paper studies the protection of the low v...

متن کامل

Piezoelectric Converters for DC/DC and AC/DC applications

This paper introduces a cutting-edge transformer technology – the piezoelectric transformer – currently considered as a potential candidate to replace magnetic transformers in resonant switching converters. Magnetic transformers are extensively used for providing step-up and step-down voltages while allowing input to output isolation in ac-dc and dc-dc converters. Even with the extensive use, t...

متن کامل

Operation of Stand Alone PV Generating System for Supplying Unbalanced AC Loads

This paper describes a DC isolated network which is fed with Distributed Generation (DG) from photovoltaic (PV) renewable sources for supplying unbalanced AC loads. The battery energy storage bank has been connected to the DC network via DC/DC converter to control the voltage of the network and optimize the operation of the PV generation units. The PV arrays are connected to the DC network ...

متن کامل

Modified Bi-directional AC/DC Power Converter with Power Factor Correction

Most existing power  converters and industrial motor drive systems draw non-sinusoidal currents from the supply. Non-sinusoidal currents contained harm harmonics disturb the power supply which it causes serious concern for reliability. Other equipments that use the same power supply are adversely affected. This paper suggests the operation and performance of a new modified AC/DC converter that ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008