Standardization, Calibration, and Control in Flow Cytometry.

نویسندگان

  • Lili Wang
  • Robert A Hoffman
چکیده

Because flow cytometers are designed to measure particle characteristics, particles are the most common materials used to calibrate, control, and standardize the instruments. Definitions and cautions are provided for common terms to alert the reader to critical distinctions in meaning. This unit presents extensive background on particle types and cautions and describes practical aspects of methods to standardize and calibrate instruments. Procedures are provided to characterize performance in terms of optical alignment, fluorescence and light scatter resolution, and sensitivity. Finally, suggestions follow for analyzing particles used for calibration. © 2017 by John Wiley & Sons, Inc.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A scalable platform for clinical immunophenotyping: assay design and quality control for high complexity flow cytometry

In the early 1980’s it was demonstrated that density gradient isolation of peripheral blood mononuclear cells led to an unpredictable loss of lymphocyte populations and unacceptable levels of error for even routine CD4+ and CD8+ T cell enumeration. The error associated with this manipulation was further amplified by errors associated with cryopreservation. Based on these results, clinical flow ...

متن کامل

Polarization of scatter and fluorescence signals in flow cytometry.

BACKGROUND The pulses of light scatter and fluorescence measured in flow cytometers exhibit varying degrees of polarization. Flow cytometers are heterogeneously sensitive to this polarization, depending on the light source(s), the optical layout, and the types of mirrors and filters used. Therefore, fluorescence polarization can affect apparent intensity ratios between particles and interfere w...

متن کامل

The development of quantum dot calibration beads and quantitative multicolor bioassays in flow cytometry and microscopy.

The use of fluorescence calibration beads has been the hallmark of quantitative flow cytometry. It has enabled the direct comparison of interlaboratory data as well as quality control in clinical flow cytometry. In this article, we describe a simple method for producing color-generalizable calibration beads based on streptavidin functionalized quantum dots. Based on their broad absorption spect...

متن کامل

Simplified protocol for flow cytometry analysis of fluorescently labeled exosomes and microvesicles using dedicated flow cytometer

Flow cytometry is a powerful method, which is widely used for high-throughput quantitative and qualitative analysis of cells. However, its straightforward applicability for extracellular vesicles (EVs) and mainly exosomes is hampered by several challenges, reflecting mostly the small size of these vesicles (exosomes: ~80-200 nm, microvesicles: ~200-1,000 nm), their polydispersity, and low refra...

متن کامل

Extracellular Vesicle Flow Cytometry Analysis and Standardization

The term extracellular vesicles (EVs) describes membranous vesicles derived from cells, ranging in diameter from 30 to 1,000 nm with the majority thought to be in the region of 100-150 nm. Due to their small diameter and complex and variable composition, conventional techniques have struggled to accurately count and phenotype EVs. Currently, EV characterization using high-resolution flow cytome...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Current protocols in cytometry

دوره 79  شماره 

صفحات  -

تاریخ انتشار 2005