Clinical comparison of the Isolator 1.5 microbial tube and the BACTEC radiometric system for detection of bacteremia in children.
نویسنده
چکیده
The Isolator 1.5 microbial tube (E. I. du Pont de Nemours & Co., Inc., Wilmington , Del.) was compared with the BACTEC radiometric detection system (Johnston Laboratories, Inc., Cockeysville, Md.) for the detection of bacteremia in children. The Isolator 1.5 is a blood culture system designed for small volumes of blood (0.5 to 1.5 ml). The method involves lysis of the cells of the patient and the direct plating of the entire blood lysate on agar media appropriate for the growth of fastidious microorganisms. Of 1,500 paired samples inoculated into the two systems, 68 were positive for 73 clinically significant organisms. The Isolator 1.5 recovered 81% of the positive cultures compared with 84% recovered by the BACTEC system. When paired blood samples with disproportionate volumes were excluded, the Isolator 1.5 detected 3% more positive cultures. More isolates of Streptococcus pneumoniae and Neisseria meningitidis were recovered by the Isolator 1.5, whereas Haemophilus influenzae was recovered most often in the BACTEC bottles (P greater than 0.1). The contamination rates were 8.7 and 3.1% for the Isolator 1.5 and the BACTEC system, respectively. In cultures positive by both systems, the mean time to detection was 4.1 h faster with the Isolator 1.5. The mean time to obtain isolated colonies was 26.6 h faster with the Isolator 1.5. These data indicate the potential value of the Isolator 1.5 microbial tube as a simple, rapid, and sensitive method for the detection of bacteremia in children.
منابع مشابه
Comparison of BACTEC 9240 Peds Plus medium and isolator 1.5 microbial tube for detection of Brucella melitensis from blood cultures.
The sensitivity and time to detection of Brucella melitensis by the BACTEC 9240 and the Isolator blood culture systems were compared in a prospective volume-controlled study. Blood sample aliquots, obtained from children with suspected brucellosis, were inoculated into a BACTEC 9240 Peds Plus bottle and into an Isolator 1.5 Microbial Tube. Overall, 122 pairs of blood samples for culture were ob...
متن کاملControlled comparison of BACTEC 13A, MYCO/F LYTIC, BacT/ALERT MB, and ISOLATOR 10 systems for detection of mycobacteremia.
To compare the performance of the BACTEC 13A (Becton Dickinson, Sparks, Md.), BACTEC MYCO/F LYTIC (Becton Dickinson), BacT/ALERT MB (bioMérieux, Durham, N.C.), and ISOLATOR 10 lysis-centrifugation (Wampole Laboratories, Cranbury, N.J.) systems for detection of mycobacteremia in adults, we inoculated 5-ml aliquots of blood from patients with suspected mycobacteremia into the bottle or tube requi...
متن کاملClinical laboratory comparison of the 10-ml isolator blood culture system with BACTEC radiometric blood culture media.
The efficiency of the 10-ml Isolator (E. I. du Pont de Nemours & Co., Inc.) for recovery of pathogens from blood was compared with that of BACTEC 6B and 7C media (Johnston Laboratories) by using 4,195 cultures from 1,662 patients. During the first phase of the study, BACTEC bottles were inoculated with 3 ml of blood; in the second phase, bottles were inoculated with 5 ml. The objectives were to...
متن کاملClinical comparison of Sentinel, a novel blood culture system, with radiometric Bactec 460 and Isolator 10 in the detection of streptococcal and anaerobic bacteraemias.
AIMS To compare the performance of the Sentinel blood culture system with two other systems for the recovery of streptococci and anaerobes. METHODS Blood cultures were taken from 55 patients one to two minutes after dental extraction. The samples were tested by the radiometric Bactec 460; the Isolator 10, which works by lysis centrifugation; and Sentinel, a fully automated system, which detec...
متن کاملControlled comparison of BacT/Alert MB system, manual Myco/F lytic procedure, and isolator 10 system for diagnosis of Mycobacterium tuberculosis Bacteremia.
We compared the performance of the BacT/Alert MB system, that of the manual Bactec Myco/F Lytic procedure, and that of the Isolator 10 lysis-centrifugation system in the detection of Mycobacterium tuberculosis bacteremia. Mean times to detection were 16.4 days for BacT/Alert MB versus 20.0 days for Myco/F Lytic, 16.5 days for BacT/Alert MB versus 23.8 days for Isolator 10, and 21.1 days for Bac...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 19 5 شماره
صفحات -
تاریخ انتشار 1984