Design of a cyclic pressure bioreactor for the ex vivo study of aortic heart valves.
نویسندگان
چکیده
The aortic valve, located between the left ventricle and the aorta, allows for unidirectional blood flow, preventing backflow into the ventricle. Aortic valve leaflets are composed of interstitial cells suspended within an extracellular matrix (ECM) and are lined with an endothelial cell monolayer. The valve withstands a harsh, dynamic environment and is constantly exposed to shear, flexion, tension, and compression. Research has shown calcific lesions in diseased valves occur in areas of high mechanical stress as a result of endothelial disruption or interstitial matrix damage(1-3). Hence, it is not surprising that epidemiological studies have shown high blood pressure to be a leading risk factor in the onset of aortic valve disease(4). The only treatment option currently available for valve disease is surgical replacement of the diseased valve with a bioprosthetic or mechanical valve(5). Improved understanding of valve biology in response to physical stresses would help elucidate the mechanisms of valve pathogenesis. In turn, this could help in the development of non-invasive therapies such as pharmaceutical intervention or prevention. Several bioreactors have been previously developed to study the mechanobiology of native or engineered heart valves(6-9). Pulsatile bioreactors have also been developed to study a range of tissues including cartilage(10), bone(11) and bladder(12). The aim of this work was to develop a cyclic pressure system that could be used to elucidate the biological response of aortic valve leaflets to increased pressure loads. The system consisted of an acrylic chamber in which to place samples and produce cyclic pressure, viton diaphragm solenoid valves to control the timing of the pressure cycle, and a computer to control electrical devices. The pressure was monitored using a pressure transducer, and the signal was conditioned using a load cell conditioner. A LabVIEW program regulated the pressure using an analog device to pump compressed air into the system at the appropriate rate. The system mimicked the dynamic transvalvular pressure levels associated with the aortic valve; a saw tooth wave produced a gradual increase in pressure, typical of the transvalvular pressure gradient that is present across the valve during diastole, followed by a sharp pressure drop depicting valve opening in systole. The LabVIEW program allowed users to control the magnitude and frequency of cyclic pressure. The system was able to subject tissue samples to physiological and pathological pressure conditions. This device can be used to increase our understanding of how heart valves respond to changes in the local mechanical environment.
منابع مشابه
The relevance of large strains in functional tissue engineering of heart valves.
BACKGROUND Exposing the developing tissue to flow and pressure in a bioreactor has been shown to enhance tissue formation in tissue-engineered heart valves. Animal studies showed excellent functionality in these valves in the pulmonary position. However, they lack the mechanical strength for implantation in the high-pressure aortic position. Improving the in vitro conditioning protocol is an im...
متن کاملA survey on the prevalence of heart murmurs in polo horses
Background: Cardiac murmur and subsequently cardiac failure is one of the poor-performance causes in athletic horses. Attention to murmur character is vital during heart examination. Polo is a sport which demands very high stress on horses, which may result in more stress on cardiovascular system. Objectives: In this study we assume that high pressure on polo horses makes them more susceptible ...
متن کاملComparison of Clinical Outcomes Seprate and semi continus sewing methods during and after Heart valves Surgery
Background and Aims: Various therapies and surgeries are applied in heart valve surgery, including interrupted and semi-continuous suture techniques. Therefore, this study aimed to compare the clinical implications of two methods of interrupted and semi-continuous suture techniques during and after mitral or aortic valve replacement surgery among patients referred to Department of Surgery, Scho...
متن کاملمقایسه اندازه دریچه آئورت مصنوعی نصب شده با قطر رینگ دریچه آئورت به طریقه اکوکاردیوگرافی دو بعدی بمنظور پیش بینی اندازه دریچه مصنوعی آئورت قبل از عمل جراحی
In recent socio-economic state it is not possible to have different sets of prosthetic cardiac valves available in the operating room before open-heart surgery for valvular replacement. In this study the diameter of the aortic valve ring measured in 2-D echocardiography was compared with the size of the aortic prosthetic valves implanted for the patients with aortic valvular disease. The purpos...
متن کاملINFECTIVE ENDOCARDITIS IN CHILDREN
A total of 14 cases of infective endocarditis (IE) in children aged 6 months to 10 years were seen from December 1987 to December 1992 at the pediatric unit of Ayatollah Taleghani Medical Center. The majority of patients (12 of 14) were between 5 and 10 years of age. Acyanotic congenital heart disease was known to preexist in 78.6% and rheumatic valvular heart disease in 21.4% of cases. Or...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of visualized experiments : JoVE
دوره 54 شماره
صفحات -
تاریخ انتشار 2011