Semirigid Cantilever Extension System for Splinting Implants: A Clinical Report
نویسندگان
چکیده
In mandibular edentulous patients, treatment based on immediate loading with rigid splinting in the mandible is well accepted; however, it is cost and time dependent, which sometimes limits this type of rehabilitation. To overcome these problems, the technique of immediate loading using a semirigid splinting extension system has been developed. Its advantages include low cost, technical feasibility, and reduced clinic time. This clinical report presents the applicability and the predictability of semirigid splinting of implants in the mandibular arch of an edentulous patient using a distal extension bar prosthesis system.
منابع مشابه
Study of the flexural sensitivity and resonant frequency of an inclined AFM cantilever with sidewall probe
The resonant frequency and sensitivity of an atomic force microscope (AFM) cantilever with assembled cantilever probe (ACP) have been analyzed and a closed-form expression for the sensitivity of vibration modes has been obtained. The proposed ACP comprises an inclined cantilever and extension, and a tip located at the free end of the extension, which makes the AFM capable of topography at sidew...
متن کاملStudy of the flexural sensitivity and resonant frequency of an inclined AFM cantilever with sidewall probe
The resonant frequency and sensitivity of an atomic force microscope (AFM) cantilever with assembled cantilever probe (ACP) have been analyzed and a closed-form expression for the sensitivity of vibration modes has been obtained. The proposed ACP comprises an inclined cantilever and extension, and a tip located at the free end of the extension, which makes the AFM capable of topography at sidew...
متن کاملBone level changes at implants supporting crowns or fixed partial dentures with or without cantilevers.
OBJECTIVE The aim of this study was to analyze whether or not a cantilever extension on a fixed dental prosthesis (FDP) supported by implants increased the amount of peri-implant bone loss or technical complications compared with reconstructions without cantilevers. MATERIALS AND METHODS Fifty-four partially dentate patients with a total of 54 FDPs supported by 78 implants were enrolled in th...
متن کاملPostoperative therapy after metacarpophalangeal arthroplasty.
A literature review was conducted to determine the most effective postoperative therapy regimens for metacarpophalangeal (MCP) arthroplasty. The main difference between the regimens was the use of passive MCP extension over active extension and splinting in MCP flexion over splinting in extension. One study did not find continuous passive motion to be significantly beneficial for gaining hand s...
متن کاملClinical and Radiological Comparison of Semirigid (WavefleX) and Rigid System for the Lumbar Spine
OBJECTIVE Spinal fusion operation is an effective treatment in the spinal pathology, but it could change the physiological distribution of load at the instrumented and adjacent segments. This retrospective study compared the radiological and clinical outcomes of patients undergoing lumbar fusion with semirigid rods versus rigid rods system. METHODS Using transpedicular fixation and posterior ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2014 شماره
صفحات -
تاریخ انتشار 2014