Breast dosimetry using high-resolution voxel phantoms.

نویسندگان

  • D R Dance
  • R A Hunt
  • P R Bakic
  • A D A Maidment
  • M Sandborg
  • G Ullman
  • G Alm Carlsson
چکیده

A computer model of X-ray mammography has been developed, which uses quasi-realistic high-resolution voxel phantoms to simulate the breast. The phantoms have 400 microm voxels and simulate the three-dimensional distributions of adipose and fibro-glandular tissues, Cooper's ligaments, ducts and skin and allow the estimation of dose to individual tissues. Calculations of the incident air kerma to mean glandular dose conversion factor, g, were made using a Mo/Mo spectrum at 28 kV for eight phantoms in the thickness range 40-80 mm and of varying glandularity. The values differed from standard tabulations used for breast dosimetry by up to 43%, because of the different spatial distribution of glandular tissue within the breast. To study this further, additional voxel phantoms were constructed, which gave variations of between 9 and 59% compared with standard values. For accurate breast dosimetry, it is therefore very important to take the distribution of glandular tissues into account.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative study of computational dosimetry involving homogeneous phantoms and a voxel phantom in mammography: a discussion on applications in constancy tests and calculation of glandular dose in patients*

OBJECTIVE: To compare data regarding dosimetry and photons fluence in different breast phantoms, discussing constancy tests and dosimetry applied to mammography. MATERIALS AND METHODS: Different homogeneous breast phantoms and one anthropomorphic voxel phantom were developed for collection of data regarding total absorbed dose in the phantom, absorbed dose in the glandular tissue material-equiv...

متن کامل

Hybrid Phantom Applications to Nuclear Medicine

Annually, many people are irradiated for diagnostic and therapeutic purposes. Assessment of radiation dose and its related risks to patients are important issues in radiation protection dosimetry. The complex mathematical calculations of the absorbed and effective doses are now done with computers. The calculations are performed with the help of anthropomorphic computational models of human bod...

متن کامل

Optimized generation of high resolution breast anthropomorphic software phantoms.

PURPOSE The authors present an efficient method for generating anthropomorphic software breast phantoms with high spatial resolution. Employing the same region growing principles as in their previous algorithm for breast anatomy simulation, the present method has been optimized for computational complexity to allow for fast generation of the large number of phantoms required in virtual clinical...

متن کامل

A quality assurance program for an amorphous silicon electronic portal imaging device using in-house developed phantoms: a method development for dosimetry purposes

Background: Electronic portal imaging devices (EPIDs) play an important role in radiation therapy portal imaging, geometric and dosimetric verifications. A successful utilization of EPIDs for imaging and dosimetric purposes requires a reliable quality control process routine to be carried out regularly. In this study, two in-house phantoms were developed and analyzed for implementation in a qua...

متن کامل

Developing the Adult Male ICRP Phantom and Evaluation the Absorbed Dose Received By Critical Organs in Head and Neck Region during the Radiotherapy of Eye Cancer

Introduction Accurate estimation of the absorbed dose in radiosensitive organs, located away from the target volume during radiotherapy, is one of the main reasons for the development of reference phantoms. The International Commission on Radiological Protection (ICRP) reference phantoms can provide a more realistic view of the human anatomy in comparison with the previously used mathematical p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 114 1-3  شماره 

صفحات  -

تاریخ انتشار 2005