Evaluation of the Ex-PRESS(®) P-50 implant under scleral flap in combined cataract and glaucoma surgery.
نویسندگان
چکیده
AIM To evaluate the efficacy and safety of glaucoma drainage device Ex-PRESS(®) P-50 for combined cataract surgery and glaucoma. METHODS Patients having cataract and open angle glaucoma or patients with open advanced glaucoma which needed two or more antiglaucoma medications were included. Combined cataract surgery and glaucoma with Ex-PRESS(®) P-50 model placed under scleral flap was performed. RESULTS Out of 40 eyes of 40 patients (55% male and 45% female) completed the study during one-year follow-up. The mean of age was 76.6±11.02y. The intraocular pressure (IOP) decreased significantly during the 12-month follow-up from 23.5 mm Hg to 16.8 mm Hg (Wilcoxon signed ranks test, P<0.001). A 59.5% of patients did not need any topical treatment, 10.8% of them needed one active principle, 27% needed two active principles, and 2.7% of them needed three active principles for successful IOP control (<21 mm Hg). CONCLUSION Combined surgery of phacoemulsification with ExPRESS(®) P-50 lowers IOP from the preoperative baseline and reduces significantly the number of antiglaucoma active principles for IOP control after the operation.
منابع مشابه
[Postoperative outcomes after combined glaucoma surgery. Comparison of ex-press miniature implant with standard trabeculectomy].
PURPOSE To evaluate postoperative outcomes and success after combined phacoemulsification and glaucoma surgery with Ex-PRESS miniature implant compared with combined surgery with standard trabeculectomy. METHODS In this prospective series of 40 consecutive eyes we compared 20 eyes in 17 patients treated with combined phacoemulsification and glaucoma filtering surgery with the Ex-PRESS miniatu...
متن کاملEvaluation of Ex-PRESS implantation combined with phacoemulsification in primary angle-closure glaucoma
To evaluate the safety and efficacy of Ex-PRESS (R50) implantation combined with phacoemulsification in primary angle-closure glaucoma (PACG) patients with cataract.Twenty-four eyes of 24 patients with unregulated PACG underwent combined cataract and glaucoma surgery. After phacoemulsification and intraocular lens implantation, the Ex-PRESS (R-50) was inserted into the anterior chamber under a ...
متن کاملLarge spot transpupillary thermotherapy for occult choroidal neovascularization.
1. Nyska A, Glovinsky Y, Belkin M, Epstein Y. Biocompatibility of the Ex-PRESS miniature glaucoma drainage implant. J Glaucoma. 2003;12: 275-280. 2. Mermoud A, Rivier D. The ExPRESS miniature glaucoma implant in combined surgery with cataract extraction: a prospective study. Paper presented at: Annual Meeting of the American Academy of Ophthalmology; October 2002; Orlando, Fla. 3. Wamsley S, Mo...
متن کاملInsertion of a foldable hydrophobic IOL through the trabeculectomy fistula in cases with Microincision cataract surgery combined with trabeculectomy
BACKGROUND The use of conventional foldable hydrophobic intraocular lenses (IOLs) in microincision cataract surgery (MICS) currently requires wound enlargement. We describe a combined surgical technique of MICS and trabeculectomy with insertion of a foldable IOL through the trabeculectomy fistula. METHODS After completion of MICS through two side port incisions, a 3.2 mm keratome is used to e...
متن کاملThe first report on intermediate-term outcome of Ex-PRESS® glaucoma filtration device implanted under scleral flap in Japanese patients
PURPOSE This paper compares the outcomes of the Ex-PRESS(®) Glaucoma Filtration Device (Alcon, Fort Worth, TX) implant observed in Japanese patients for 1 year with those of patients undergoing trabeculectomy. PATIENTS AND METHODS The subjects comprised ten eyes of ten cases with open-angle glaucoma for which filtration surgery using Ex-PRESS (P-50) was performed by one operator from February...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of ophthalmology
دوره 9 4 شماره
صفحات -
تاریخ انتشار 2016