Relative Measurement of Differential Electrode Impedance for Contact Monitoring in a Biopotential Amplifier 601 Relative Measurement of Differential Electrode Impedance for Contact Monitoring in a Biopotential Amplifier
نویسنده
چکیده
In this paper, we propose a simple and relative electrode contact monitoring method. By exploiting the power line interference, which is regarded as one of the worst noise sources for bio-potential measurement, the relative difference in electrode impedance can be measured without a current or voltage source. Substantial benefits, including no extra circuit components, no degradation of the body potential driving circuit, and no electrical safety problem, can be achieved using this method. Furthermore, this method can be applied to multi-channel isolated bio-potential measurement systems and home health care devices under a steady measuring environment.
منابع مشابه
An active electrode for biopotential recording from small localized bio-sources
BACKGROUND Laser bio-stimulation is a well-established procedure in Medical Acupuncture. Nevertheless there is still a confusion as to whether it works or the effect is just placebo. Although a plethora of scientific papers published, showing positive clinical results, there is still a lack of objective scientific proofs about the bio-stimulation effect of lasers used in Acupuncture. The object...
متن کاملIlkka Hokajärvi Electrode Contact Impedance and Biopotential Signal Quality
TAMPERE UNIVERSITY OF TECHNOLOGY Master’s Degree Programme in Electrical Engineering ILKKA HOKAJÄRVI: Electrode Contact Impedance and Biopotential Signal Quality Master of Science Thesis, 66 pages, 3 Appendix pages September 2012 Major: Biomedical Engineering Examiner: Professor Jari Hyttinen
متن کاملNovel dry electrodes for ECG monitoring.
The development, fabrication and characterization of two novel dry bioelectrodes--conductive and capacitive ones--for biopotential monitoring are presented. The new electrodes have the potential to improve the applicability of dry electrodes in ambulant recording of ECG by reducing motion artifacts as well as the contact impedance to the skin. Furthermore, a passive filter network is integrated...
متن کاملAn Ultra High CMRR Low Voltage Low Power Fully Differential Current Operational Amplifier (COA)
this paper presents a novel fully differential (FD) ultra high common mode rejection ratio (CMRR) current operational amplifier (COA) with very low input impedance. Its FD structure that attenuates common mode signals over all stages grants ultra high CMRR and power supply rejection ratio (PSRR) that makes it suitable for mixed mode and accurate applications. Its performance is verified by HSPI...
متن کاملFully Integrated Biopotential Acquisition Analog Front-End IC
A biopotential acquisition analog front-end (AFE) integrated circuit (IC) is presented. The biopotential AFE includes a capacitively coupled chopper instrumentation amplifier (CCIA) to achieve low input referred noise (IRN) and to block unwanted DC potential signals. A DC servo loop (DSL) is designed to minimize the offset voltage in the chopper amplifier and low frequency respiration artifacts...
متن کامل