Defining Optimal Head-Tilt Position of Resuscitation in Neonates and Young Infants Using Magnetic Resonance Imaging Data

نویسندگان

  • Utpal S. Bhalala
  • Malvi Hemani
  • Meehir Shah
  • Barbara Kim
  • Brian Gu
  • Angelo Cruz
  • Priya Arunachalam
  • Elli Tian
  • Christine Yu
  • Joshua Punnoose
  • Steven Chen
  • Christopher Petrillo
  • Alisa Brown
  • Karina Munoz
  • Grant Kitchen
  • Taylor Lam
  • Thangamadhan Bosemani
  • Thierry A. G. M. Huisman
  • Robert H. Allen
  • Soumyadipta Acharya
چکیده

Head-tilt maneuver assists with achieving airway patency during resuscitation. However, the relationship between angle of head-tilt and airway patency has not been defined. Our objective was to define an optimal head-tilt position for airway patency in neonates (age: 0-28 days) and young infants (age: 29 days-4 months). We performed a retrospective study of head and neck magnetic resonance imaging (MRI) of neonates and infants to define the angle of head-tilt for airway patency. We excluded those with an artificial airway or an airway malformation. We defined head-tilt angle a priori as the angle between occipito-ophisthion line and ophisthion-C7 spinous process line on the sagittal MR images. We evaluated medical records for Hypoxic Ischemic Encephalopathy (HIE) and exposure to sedation during MRI. We analyzed MRI of head and neck regions of 63 children (53 neonates and 10 young infants). Of these 63 children, 17 had evidence of airway obstruction and 46 had a patent airway on MRI. Also, 16/63 had underlying HIE and 47/63 newborn infants had exposure to sedative medications during MRI. In spontaneously breathing and neurologically depressed newborn infants, the head-tilt angle (median ± SD) associated with patent airway (125.3° ± 11.9°) was significantly different from that of blocked airway (108.2° ± 17.1°) (Mann Whitney U-test, p = 0.0045). The logistic regression analysis showed that the proportion of patent airways progressively increased with an increasing head-tilt angle, with > 95% probability of a patent airway at head-tilt angle 144-150°.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Brain Magnetic Resonance Imaging (MRI) Findings of Neonates with Clinical Seizure Admitted to Yazd Shahid Sadoughi Hospital and its Effect on Diagnostic and Therapeutic Interventions of Newborns from 2015-2016

Introduction: In neonatal period, brain magnetic resonance imaging (MRI) is the best neuroimaging to find etiology of seizure. The aim of this study was to evaluate brain MRI findings of neonates with clinical seizure and its effect on diagnostic and therapeutic interventions of newborn. Methods: In a retrospective study, medical records and brain MRI findings of neonates with clinical seizure...

متن کامل

Neonatal Brain Magnetic Resonance Imaging Findings and Its Relationship with Demographic Characteristics of Neonates

Background and Objective: Neonatal neurological diseases are characterized by a range of clinical symptoms and signs that can be confirmed by Magnetic Resonance Imaging (MRI) in some cases. This study aimed to examine the neonatal cerebral MRI descriptively. Materials and Methods: In this comparative cross-sectional study, 69 MRI neonatal images were analyzed from January to April 2019. These ...

متن کامل

Analysis of Memory-Related Brain Activation Maps in Sleep-Depriveation using Functional Magnetic Resonance Imaging

Background and purpose: Insomnia is a common sleep disorder with negative consequences such as decreased quality of life. In this study, the effect of sleep deprivation on memory in both young and older adults was investigated using functional magnetic resonance imaging (fMRI). Materials and methods: In this retrospective study, fMRI data of 40 healthy subjects (17 young and 23 older people) w...

متن کامل

بررسی شدت نسبی سیگنال تصاویر Magnetic Resonance در بافت رترودیسکال و عضله پتریگوئید خارجی و رابطه آن با یافته‌های Magnetic Resonance Imaging

Background and Aims: Disc displacement is the most common temporomandibular joint disorder and magnetic resonance imaging (MRI) is the gold standard in its diagnosis. This disorder can lead to changes in signal intensity of magnetic resonance (MR). The purpose of this study was evaluation of correlation between relative signal intensity of MR images of retrodiscal tissue, superior and inferior ...

متن کامل

Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)

Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016