Assessment of tilt and decentration of crystalline lens and intraocular lens relative to the corneal topographic axis using anterior segment optical coherence tomography
نویسندگان
چکیده
PURPOSE To investigate the tilt and decentration of the crystalline lens and the intraocular lens (IOL) relative to the corneal topographic axis using anterior segment ocular coherence tomography (AS-OCT). METHODS A sample set of 100 eyes from 49 subjects (41 eyes with crystalline lenses and 59 eyes with IOLs) were imaged using second generation AS-OCT (CASIA2, TOMEY) in June and July 2016 at Okayama University. Both mydriatic and non-mydriatic images were obtained, and the tilt and decentration of the crystalline lens and the IOL were quantified. The effects of pupil dilation on measurements were also assessed. RESULTS The crystalline lens showed an average tilt of 5.15° towards the inferotemporal direction relative to the corneal topographic axis under non-mydriatic conditions and 5.25° under mydriatic conditions. Additionally, an average decentration of 0.11 mm towards the temporal direction was observed under non-mydriatic conditions and 0.08 mm under mydriatic conditions. The average tilt for the IOL was 4.31° towards the inferotemporal direction relative to the corneal topographic axis under non-mydriatic conditions and 4.65° in the same direction under mydriatic conditions. The average decentration was 0.05 mm towards the temporal direction under non-mydriatic conditions and 0.08 mm in the same direction under mydriatic conditions. A strong correlation was found between the average tilt and decentration values of the crystalline lens and the IOL under both non-mydriatic and mydriatic conditions (all Spearman correlation coefficients, r ≥ 0.800; all P < 0.001). CONCLUSION When measured using second generation AS-OCT, both the crystalline lens and the IOL showed an average tilt of 4-6° toward the inferotemporal direction relative to the corneal topographic axis and an average decentration of less than 0.12 mm towards the temporal direction. These results were not influenced by pupil dilation and they showed good repeatability.
منابع مشابه
P 230 Endothelial response and bloo-aqueous barrier breakdown following phacoemulsification
MEASUREMENT OF CORNEAL AND CRYSTALLINE LENS MISALIGNMENT RELATIVE TO THE VISUAL AXIS DUNNE M.C.M.1, BARRY J.C.2, HARTMANN A.2, CULPIN F.1, DE MAIN J.l, DUKE A.1 and FRENCH 1.1 I Department of Vision Sciences, Aston University (UK) 2 Department of Ophthalmology, RUTH Aachen (Germany) %rpare To measure the misalignment between the comeal and crystalline lens axes relative to the visual axis. To e...
متن کاملIntraocular lens alignment from an en face optical coherence tomography image Purkinje-like method
Mengchan Sun Alberto de Castro Sergio Ortiz Pablo Perez-Merino Judith Birkenfeld Susana Marcos Instituto de Óptica “Daza de Valdés” Consejo Superior de Investigaciones Científicas Serrano 121 28006 Madrid, Spain E-mail: [email protected] Abstract. Measurement of intraocular lens (IOL) alignment implanted in patients in cataract surgery is important to understand their optical performance....
متن کاملFull OCT anterior segment biometry: an application in cataract surgery
In vivo three-dimensional (3-D) anterior segment biometry before and after cataract surgery was analyzed by using custom high-resolution high-speed anterior segment spectral domain Optical Coherence Tomography (OCT). The system was provided with custom algorithms for denoising, segmentation, full distortion correction (fan and optical) and merging of the anterior segment volumes (cornea, iris, ...
متن کاملIOL Tilt and Decentration Estimation from 3 Dimensional Reconstruction of OCT Image
PURPOSE To evaluate intraocular lens (IOL) tilt and decentration by anterior segment optical coherence tomography (AS-OCT) using 3-dimensional (3D) reconstruction method. DESIGN Prospective observational case series. PARTICIPANTS Thirty-nine patients (39 eyes) were included. METHODS The IOL positions of all eyes were examined by AS-OCT. Images were obtained in 4 axes (0-180 degrees, 45-22...
متن کاملEvaluation of scleral-fixated intraocular lens position anomalies by anterior segment optical coherence tomography.
BACKGROUND/AIM To measure the positions of scleral-fixated intraocular lenses (IOLs) using anterior segment optical coherence tomography (OCT) and to evaluate the influence of the position of scleral-fixated IOL on the quality of vision. MATERIALS AND METHODS Twenty-six eyes of 26 patients were included in the study. The average age was 57.5 (11 to 78) years. Anterior segment images were take...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 12 شماره
صفحات -
تاریخ انتشار 2017