A Hygroscopic Sensor Electrode for Fast Stabilized Non-Contact ECG Signal Acquisition
نویسندگان
چکیده
A capacitive electrocardiography (cECG) technique using a non-invasive ECG measuring technology that does not require direct contact between the sensor and the skin has attracted much interest. The system encounters several challenges when the sensor electrode and subject's skin are weakly coupled. Because there is no direct physical contact between the subject and any grounding point, there is no discharge path for the built-up electrostatic charge. Subsequently, the electrostatic charge build-up can temporarily contaminate the ECG signal from being clearly visible; a stabilization period (3-15 min) is required for the measurement of a clean, stable ECG signal at low humidity levels (below 55% relative humidity). Therefore, to obtain a clear ECG signal without noise and to reduce the ECG signal stabilization time to within 2 min in a dry ambient environment, we have developed a fabric electrode with embedded polymer (FEEP). The designed hygroscopic FEEP has an embedded superabsorbent polymer layer. The principle of FEEP as a conductive electrode is to provide humidity to the capacitive coupling to ensure strong coupling and to allow for the measurement of a stable, clear biomedical signal. The evaluation results show that hygroscopic FEEP is capable of rapidly measuring high-accuracy ECG signals with a higher SNR ratio.
منابع مشابه
Belt-type Wireless and Non-contact Electrocardiogram Monitoring System Using Flexible Active Electrode
Electrocardiogram (ECG) measurement using capacitively coupled electrode is a well-know method to get the ECG signal without direct skin-contact. In this paper, the belt-type system which measures ECG without direct skin-contact is designed and tested. The system consists of developed flexible active electrode (FAE), a driven-right-leg electrode and a module for signal processing and data acqui...
متن کاملIntegrated Sensors for Wireless Non-contact Cardiac and Neural (ECG/EEG) Monitoring – TATRC Grand Challenge
Wearable, unobtrusive physiological and cognitive monitoring systems have significant potential for increasing the effectiveness of military and civilian medical care by providing real-time and continuous data for key vital signs. To date, however, such systems have been constrained by the need for extensive subject preparation along with the discomfort and inconvenience of skin-adhesive electr...
متن کاملساخت حسگر پارچهای سیگنال قلب توسط چاپ و لایه نشانی فلز مس روی پارچه پلیاستر
In the last decade, a significant progress has been made in the wearable medical devices. Scientists are extensively involved in the design of the flexible instruments equipped with garments to fulfill the daily needs and requirements. The fulfillment of this demand particularly needs a conductive fabric substrate with a high level of homogeneity, and the lowest barrier against electrical curre...
متن کاملGraphene-Enabled Electrodes for Electrocardiogram Monitoring
The unique parameters of graphene (GN)-notably its considerable electron mobility, high surface area, and electrical conductivity-are bringing extensive attention into the wearable technologies. This work presents a novel graphene-based electrode for acquisition of electrocardiogram (ECG). The proposed electrode was fabricated by coating GN on top of a metallic layer of a Ag/AgCl electrode usin...
متن کاملPalm-based ECG biometrics
We propose an experimental apparatus for ECG biometrics, that matches the usability and intrusiveness levels of traditional biometric traits like fingerprint or hand geometry centered on subject’s hand or fingers, and that require some degree of contact of proximity to the sensoring device. A hardware device was developed, comprised of a surface with integrated electrodes and signal conditionin...
متن کامل