Quantification of strontium in plasma and urine with flameless atomic absorption spectrometry.

نویسندگان

  • O R Leeuwenkamp
  • W J van der Vijgh
  • B C Hüsken
  • P Lips
  • J C Netelenbos
چکیده

This analytical method for determination of Sr in plasma and urine involves flameless atomic absorption spectrophotometry (FAAS). Drying, charring, and atomization were optimized with respect to temperature, temperature ramp, and duration for Sr in dilute HNO3 and Sr in plasma diluted 20-fold with dilute HNO3. Calibration curves (r greater than 0.995) were linear in the concentration range 5-250 micrograms/L for Sr in various media, with intercepts negligibly small except for the calibration curves in 1:1-diluted plasma and undiluted urine. The estimated detection limits for Sr in 20-fold-diluted plasma and 50-fold-diluted urine were 2 and 3 micrograms/L, respectively. Endogenous Sr in plasma and urine was estimated at 16 (SD 8) micrograms/L and 158 (SD 26) micrograms/L (n = 6), respectively. Intra- and interassay CVs were 9.1% and 5.3% for 20-fold-diluted plasma at a Sr concentration of 25 micrograms/L, and 6.9% and 4.8% at a concentration of 250 micrograms/L. The respective CVs were 8.2% and 1.2% for 50-fold-diluted urine at the low concentration, and 4.0% and 4.6% at the high concentration. In a pharmacokinetic pilot study of 2.5 mmol of Sr orally administered to a healthy volunteer, the peak plasma concentration of Sr, 4.4 mg/L, decayed bi-exponentially [t1/2, alpha = 24 h, t1/2, beta = 77 h]; the estimated first-order absorption rate constant was 0.005 min-1; and the observed decay (day 0-6) of the urinary Sr/creatinine ratio closely paralleled the plasma decay [t1/2 = 70 h].

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

InterlaboratoryComparisons of Nickel Analyses in Urine by Atomic AbsorptionSpectrometry1’2’3’4

Two interlaboratory surveys of urine nickel analyses were performed in which eight or nine urine samples were distributed to laboratories in seven nations for measurements of nickel concentrations by atomic absorption spectrometry. In both surveys, wide discrepancies were observed in the values for urine nickel concentrations that were obtained in different laboratories by various analytical me...

متن کامل

Determination of diethyllead in the urine by flameless atomic absorption spectrometry.

A method for the determination of diethyllead in urine by flameless atomic absorption spectrometry after chelation with glyoxal-bis (2-hydroxyanil) and extraction of the formed complex with methyl isobutyl ketone is described. The method is specific in relation to both triethyllead and inorganic lead. The limit of detection was 3.2 micrograms Pb/l and the relative standard deviation in the conc...

متن کامل

Elimination of Chemical and Spectral Interferences in Measurement of Trace Elements in Urine and Blood by Combined Electrodeposition-Electrothermal Atomic Absorption Spectrometry

A combined electrodeposition-ETAAS technique has been applied to the analysis of Pb, Cd, Co, Ni, Cr and Mn in biological samples in order to overcome interferences and to minimize sample pretreatment. It requires minimal sample preparation with the electrolysis process aiding partial decomposition of the organic matrix, adequate for the release and deposition of trace elements. In an initia...

متن کامل

Analysis for platinum in biological material by flameless atomic absorption spectrometry.

A method for determining platinum in biological materials by flameless atomic absorption spectrometry has been developed for use in pharmacological studies of platinum antitumor compounds. Tissue digests are analyzed in a heated graphite atomizer, with use of background correction and ramp temperature charring. We have overcome problems of apparent loss of platinum in Pt-supplemented tissue sam...

متن کامل

Direct determination of lead and cadmium in blood and urine by flameless atomic absorption spectrophotometry.

We describe procedures for direct determination of lead and cadmium in blood and urine by flameless atomic absorption spectrophotometry. Before analysis, the samples are pre-ashed in microboats in an ordinary laboratory oven. In this way, many samples can be prepared and pre-ashed simultaneously. We find the procedures presented in this work to be rapid, accurate, and precise.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 35 9  شماره 

صفحات  -