Accuracy of continuous noninvasive arterial pressure monitoring in living-liver donors during transplantation.

نویسندگان

  • Coskun Araz
  • Pinar Zeyneloglu
  • Arash Pirat
  • Nukhet Veziroglu
  • Aynur Camkiran Firat
  • Gulnaz Arslan
چکیده

OBJECTIVES Hemodynamic monitoring is vital during liver transplant surgeries because distinct hemodynamic changes are expected. The continuous noninvasive arterial pressure (CNAP) monitor is a noninvasive device for continuous arterial pressure measurement by a tonometric method. This study compared continuous noninvasive arterial pressure monitoring with invasive direct arterial pressure monitoring in living-liver donors during transplant. MATERIALS AND METHODS There were 40 patients analyzed while undergoing hepatic lobectomy for liver transplant. Invasive pressure monitoring was established at the radial artery and continuous noninvasive arterial pressure monitoring using a finger sensor was recorded simultaneously from the contralateral arm. Systolic, diastolic, and mean arterial pressures from the 2 methods were compared. Correlation between the 2 methods was calculated. RESULTS A total of 5433 simultaneous measurements were obtained. For systolic arterial blood pressure, 55% continuous noninvasive arterial pressure measurements were within 10% direct arterial measurement; the correlation was 0.479, continuous noninvasive arterial pressure bias was -0.3 mm Hg, and limits of agreement were 32.0 mm Hg. For diastolic arterial blood pressure, 50% continuous noninvasive arterial pressure measurements were within 10% direct arterial measurement; the correlation was 0.630, continuous noninvasive arterial pressure bias was -0.4 mm Hg, and limits of agreement were 21.1 mm Hg. For mean arterial blood pressure, 60% continuous noninvasive arterial pressure measurements were within 10% direct arterial measurement; the correlation was 0.692, continuous noninvasive arterial pressure bias was +0.4 mm Hg, and limits of agreement were 20.8 mm Hg. CONCLUSIONS The 2 monitoring techniques did not show acceptable agreement. Our results suggest that continuous noninvasive arterial pressure monitoring is not equivalent to invasive arterial pressure monitoring in donors during living-donor liver transplant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study

Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...

متن کامل

Exploring of Living Donors’ Experiences Following Liver Transplantation: a qualitative descriptive study

Background and Objectives: The main challenge in liver transplantation is shortage of donor organs, and using living donor live transplantation (LDLT) has been considered as a new strategy. This study aimed to explore the concept of liver transplantation in living donors’ experiences after donating. Materials and Methods: A qualitative study with qualitative descriptive approach was co...

متن کامل

Accuracy and precision of continuous noninvasive arterial pressure monitoring compared with invasive arterial pressure: a systematic review and meta-analysis.

BACKGROUND Continuous noninvasive arterial pressure monitoring devices are available for bedside use, but the accuracy and precision of these devices have not been evaluated in a systematic review and meta-analysis. METHODS The authors performed a systematic review and meta-analysis of studies comparing continuous noninvasive arterial pressure monitoring with invasive arterial pressure monito...

متن کامل

Accuracy and Trending of Continuous Noninvasive Hemoglobin Monitoring in Patients Undergoing Liver Transplantation.

BACKGROUND Shift in large fluid volumes and massive blood loss during liver transplantation frequently leads to rapid changes in hemoglobin (Hb) concentration; thus, to ensure adequate tissue oxygenation, accurate and rapid determination of Hb concentration is essential in transplant recipients. The Radical-7 Pulse CO-Oximeter provides a noninvasive and continuous way to monitor Hb concentratio...

متن کامل

ملاحظات اخلاقی

Background: Kidney transplantation is one of the major progresses of medical science with many ethical debates. The shortage of organs and the increases in waiting list for cadaver transplantation has leaded to transplantation from living donors. In this article, we discuss the ethics of transplantation from living kidney donors. Methods: For compiling this article, we searched in Pubmed and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Experimental and clinical transplantation : official journal of the Middle East Society for Organ Transplantation

دوره 13 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2015