Clinical validation of glucose pump test (GPT) compared with ultrasound dilution technology in arteriovenous graft surveillance.

نویسندگان

  • Alberto Magnasco
  • Giuseppe Bacchini
  • Antonio Cappello
  • Vincenzo La Milia
  • Brigida Brezzi
  • PierGiorgio Messa
  • Francesco Locatelli
چکیده

BACKGROUND Blood flow (Qa) measurements are an important step in the surveillance protocol of haemodialysis vascular access (VA). The glucose pump test (GPT) is a new test for Qa measurement based on the dilution of a constant glucose infusion. The aim of this study is to verify the clinical accuracy of GPT in a graft surveillance protocol with sequential Qa measurements. METHODS In 30 chronic haemodialysis patients with graft, we compared monthly sequential Qa measurements performed with GPT in pre-dialysis and the ultrasound dilution technique (HD01 device Transonic Systems Inc., USA) during dialysis. The colour Doppler ultrasonography study (CDU) was our reference standard for the diagnosis of stenosis. The endpoints were the graft thrombosis or PTA treatment. RESULTS According to the K/DOQI guidelines we could identify the thrombosis high-risk grafts when Qa was <600 ml/min or <1000 ml/min with a decrease >25% in serial Qa measurements. HD01 yielded 27 of 112 high-risk Qa measurements (21 Qa <600 ml/min; mean 406+/-145 ml/min; 6 deltaQa >25%; mean 43+/-7%). In 12 of 27 cases the CDU control did not show haemodynamically significant stenoses (false positive); 15 of 27 cases were confirmed high-risk accesses by CDU and did PTAs (HD01 specificity 86%). GPT yielded 14 of 112 high-risk Qa measurements (8 Qa <600 ml/min; mean 404+/-135 ml/min; 6 deltaQa >25%; mean 38+/-8%) and all had severe stenoses and underwent PTA treatments showing a GPT specificity of 100%. The CDU study allowed us to correctly assess the Qa negative cases. HD01 method had 10 false negative cases (treated or clotted grafts with a Qa >600 ml/min and deltaQa <25%) with a sensitivity of 60%, while GPT had 11 false negative cases with a sensitivity of 56%. The diagnostic accuracy tested with the ROC curves was similar with both tests (area under the curve was 0.762 and 0.752 with GPT and ultrasound dilution, respectively; P = 0.985). The diagnostic efficiency (percentage of grafts with agreement between test result and factual situation) was 90 and 80% (P = 0.056) for GPT and HD01, respectively. CONCLUSION Compared with HD01, the GPT had a lower false positive rate and similar diagnostic accuracy and efficiency. The clinical implication is a smaller number of unnecessary, invasive procedures (angiographies or PTAs), without increasing the thrombosis risk. This study has shown that GPT is an accurate, quick and economic test for Qa monitoring.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation in the sheep of an ultrasound velocity dilution technique for haemodialysis graft flow.

BACKGROUND A simple, rapid, inexpensive method for measuring the flow in a patient's vascular access would permit routine monitoring during haemodialysis, and hence provide information of access graft deterioration sufficiently early to increase the success of minimally invasive remedial procedures. This paper reports the validation of such a method in animals. METHODS A PTFE graft was implan...

متن کامل

Vascular access surveillance

Arteriovenous graft (AVG) a. Regular Access Blood Flow (Qa) or Doppler ultrasound stenosis (DUS) screening increases the detection of AVG stenosis compared to dynamic venous pressure (DVP)/clinical examination. (Level II evidence) b. Regular Qa screening with pre-emptive angioplasty does not reduce AVG thrombosis or prolong AVG survival. (Level I & II evidence) c. Whether regular DUS screening ...

متن کامل

Glucose pump test: a new method for blood flow measurements.

BACKGROUND A good test for monitoring blood flow (Q(a)) must be accurate, rapid and economical in order to allow frequent easy measurements. The glucose pump test (GPT) is based on a constant glucose infusion as a dilutional indicator of Q(a). METHODS GPT protocol requires a constant glucose infusion, by a syringe pump, into the arterial needle and two blood withdrawals from the venous needle...

متن کامل

Evaluation of Factors Influencing Liver Function Test in On-Pump Coronary Artery Bypass Graft Surgery

Background: Liver dysfunction during on-pump coronary artery bypass graft surgery (CABG) is a rare complication but is associated with significant morbidity and mortality. The ability to identify high-risk patients may be helpful in planning appropriate management strategies. We aimed to evaluate the factors influencing liver function tests during on-pump CABG.Methods: In 146 patients scheduled...

متن کامل

Computational Fluid Dynamics Simulation and Experimental Validation of Hydraulic Performance of a Vertical Suspended API Pump (RESEARCH NOTE)

For a long period of time, design and manufacturing technology of high flow rated vertically suspended pumps (VSPs) which have an extensive applications in many industries such as water and wastewater, mining, petrochemical and oil and gas industries, used to be imported from European countries. For the first time in Iran's pump industry, with the support of Ministry of Petrochemical[ah1]  and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 19 7  شماره 

صفحات  -

تاریخ انتشار 2004