Concentration ratios of morphine to codeine in blood of impaired drivers as evidence of heroin use and not medication with codeine.

نویسندگان

  • G Ceder
  • A W Jones
چکیده

BACKGROUND Both the illicit drug heroin and the prescription drug codeine are metabolized to morphine, which tends to complicate interpretation of opiate-positive samples. We report here the concentrations of morphine and codeine, the morphine/codeine ratios, and 6-acetylmorphine (6-AM) in blood specimens from individuals arrested for driving under the influence of drugs (DUID) in Sweden. The results were compared with positive findings of 6-AM in urine as evidence of heroin intake. METHODS In 339 DUID suspects, both blood and urine specimens were available for toxicologic analysis. In another 882 cases, only blood was available. All specimens were initially analyzed by immunoassay, and the positive results were verified by isotope-dilution gas chromatography-mass spectrometry. In routine casework, the limits of quantification (LOQs) for unconjugated opiates were 5 ng/g for blood and 20 microg/L for urine. RESULTS The median concentration of morphine in blood was 30 ng/g with 2.5 and 97.5 percentiles of 5 and 230 ng/g, respectively (n = 979). This compares with a median codeine concentration of 20 ng/g and 2.5 and 97.5 percentiles of 5 and 592 ng/g, respectively (n = 784). The specific metabolite of heroin, 6-AM, was identified in only 16 of 675 blood specimens (2.3%). This compares with positive findings of 6-AM in 212 of 339 urine samples (62%) from the same population of DUID suspects. When 6-AM was identified in urine, the morphine/codeine ratio in blood was always greater than unity (median, 6.0; range, 1-66). In 18 instances, 6-AM was present in urine, although morphine and codeine were below the LOQ in blood. The morphine/codeine ratio in blood was greater than unity in 85% of DUID cases when urine was not available (n = 506), and the median morphine and codeine concentrations were 70 ng/g and 10 ng/g, respectively. When morphine/codeine ratios in blood were less than unity (n = 76), the median morphine and codeine concentrations were 10 ng/g and 180 ng/g, respectively. CONCLUSIONS Only 2.3% of opiate-positive DUID suspects were verified as heroin users on the basis of positive findings of 6-AM in blood. A much higher proportion (62%) were verified heroin users from 6-AM identified in urine. When urine was not available for analysis, finding a morphine/codeine concentration ratio in blood above unity suggests heroin use and not medication with codeine. This biomarker indicated that 85% of opiate-positive DUID blood samples were from heroin users.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Driving under the influence of opiates: concentration relationships between morphine, codeine, 6-acetyl morphine, and ethyl morphine in blood.

Morphine and codeine are frequently identified in blood samples from impaired drivers. But whether these opiates reflect the use of prescription analgesics or abuse of the illicit drug heroin (diacetyl morphine) is not always obvious. Opiates, either alone or together with other drugs, were determined in 2,573 blood specimens from impaired drivers by sensitive and specific methods of analysis. ...

متن کامل

Urinary excretion of morphine and codeine following the administration of single and multiple doses of opium preparations prescribed in Taiwan as "brown mixture".

Parallel to the "poppy-seed defense" strategy commonly reported in the United States, donors of urine samples tested positive for opiates in Taiwan often claimed the consumption of Brown Mixture (BM) as the source of the observed morphine and codeine. Because BM contains opium powder (10.0-10.5% morphine), opium tincture (0.9-1.1% morphine), or camphorated opium tincture (0.045-0.055% morphine)...

متن کامل

Identifying cases of heroin toxicity where 6-acetylmorphine (6-AM) is not detected by toxicological analyses

PURPOSE Heroin has a half-life of 2-6 min and is metabolized too quickly to be detected in autopsy samples. The presence of 6-acetylmophine (6-AM) in urine, blood, or other samples is convincing evidence of heroin use by a decedent, but 6-AM itself has a half-life of 6-25 min before it is hydrolyzed to morphine, so 6-AM may not be present in sufficient concentration to detect in postmortem samp...

متن کامل

Determination of codeine and morphine in Brown Mixture (opium preparations) in Taiwan using SPE and GC/MS

Brown Mixture (BM), containing opium powder (10.0-10.5% morphine), opium tincture (0.9-1.1% morphine), or camphorated opium tincture (0.045-0.055% morphine), is a popular remedy, while heroin use is prohibited in Taiwan. Thus, for specimens that are tested positive for morphine, specimen donors' claims of BM use have to be adequately addressed. This study was designed to develop and validate a ...

متن کامل

Unexpected variation of the codeine/morphine ratio following fatal heroin overdose.

Postmortem samples from 14 cases of suspected heroin overdose were subjected to a preliminary systematic toxicological analysis in order to highlight the presence of unknown exogenous compounds (e.g., drugs of abuse, alcohol) that may have played a role in the mechanism of death. This analysis unveiled histories of poly-drug use in seven of the cases under investigation. Moreover, the concentra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 47 11  شماره 

صفحات  -

تاریخ انتشار 2001