OBJECTIVE The aim of this study is to prospectively compare the accuracies of transcranial color-coded sonography (TCCS) and transcranial Doppler (TCD) in the diagnosis of elevated intracranial pressure. METHODS A prospective, blinded, head-to-head comparison of TCD and TCCS methods using intracranial pressure (ICP) measured continuously via an intraparenchymal catheter as the reference standard in 2 groups of 20 neurocritical care patients each: high ICP (group 1) and normal ICP (group 2). Middle cerebral artery (MCA) pulsatility index (PI) recordings from all patients' sonographic reports were selected based on the highest left or right recorded MCA PI. Transcranial Doppler was performed using a dedicated TCD device, and TCCS was performed using a portable ultrasound system. RESULTS The PI values obtained did not differ significantly between the 2 methods (group 1, P = .46; group 2, P = .11). Linear regression analysis identified a significant relationship between PI obtained with both methods (r = 0.897; P < .0001). The duration of PI measurement was statistically longer with TCCS than TCD (group 1, P < .01; group 2, P < .01). Diagnostic accuracies were good and similar for both methods (TCD area under curve, 0.901; TCCS area under curve 0.870; P = .69). CONCLUSIONS This work is a pilot study comparing TCCS and TCD in the detection of elevated ICP. This study suggests that a bedside portable ultrasound system may be useful to determine MCA PI with accuracy similar to that of a dedicated TCD device.
منابع مشابه
A rapid noninvasive method of detecting elevated intracranial pressure using bedside ocular ultrasound: application to 3 cases of head trauma in the pediatric emergency department.
Managing pediatric head trauma with elevated intracranial pressure in the acute setting can be challenging. Bedside ocular ultrasound for measuring optic nerve sheath diameters has been recently proposed as a portable noninvasive method to rapidly detect increased intracranial pressure in emergency department patients with head trauma. Prior study data agree that the upper limit of normal optic...
متن کاملAccuracy of Noninvasive Intraocular Pressure or Optic Nerve Sheath Diameter Measurements for Predicting Elevated Intracranial Pressure in Cryptococcal Meningitis
BACKGROUND Cryptococcal meningitis is associated with increased intracranial pressure (ICP). Therapeutic lumbar puncture (LP) is recommended when the initial ICP is >250 mm H2O, yet the availability of manometers in Africa is limited and not always used where available. We assessed whether intraocular pressure could be a noninvasive surrogate predictor to determine when additional therapeutic L...
متن کاملNoninvasive estimation of intracranial pressure using TCD
Usefulness of transcranial Doppler-derived cerebral hemodynamic parameters in the noninvasive assessment of intracranial pressure. Author Wakerley BR1, Kusuma Y, Yeo LL, Liang S, Kumar K, Sharma AK, Sharma VK. Content/Summary Abstract BACKGROUND: Transcranial Doppler (TCD) ultrasonography is a noninvasive bedside tool that can evaluate cerebral blood flow hemodynamics in major intracranial arte...
متن کاملInvestigation of sympathetic mechanism of inverse relationship between scalp and leg blood flow with increasing intracranial pressure in the rabbit
Intracranial pressure (ICP) is one of most important factors in determining health and function of cerebroscular system. However the methods of measuring ICP are usually invasive . In an attempt to find a noninvasive method to assess ICP, in previous study web found a reverse relationships between changes in ICP and blood flow in scalp (SBF) and leg skin (LSBF) . In this study the role of sympa...
متن کاملOptic Nerve Sheath Diameter as a Bedside Assessment for Elevated Intracranial Pressure
A previously fit and healthy 26-year-old lady with no significant medical history presented with a two-month history of headaches. The headaches were prolonged, generalised, and unusually severe for the patient. Examination revealed papilloedema. The patient's optic nerve sheath diameter was measured 3 mm posterior to the globe and found to be 7.5 mm. The patient subsequently had computed tomog...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The American journal of emergency medicine
دوره 30 1 شماره
صفحات -
تاریخ انتشار 2012