Sacral screw loads in lumbosacral fixation for spinal deformity.

نویسندگان

  • R S Pashman
  • S S Hu
  • M J Schendel
  • D S Bradford
چکیده

Fixation to the sacrum and pelvis is a problem in the operative treatment of spinal deformity. Previous testing of pedicle screws address axial pull-out strength, yet how screws are loaded in vivo remains unknown. The goals of this study were to determine the loads experienced by sacral screws when loaded as part of Cotrel-Dubousset (CD) sacral instrumentation and whether different anterior grafting methods would effect screw loads. Sacral screws were modified to become transducers capable of measuring axial and bending loads. The screw transducers were incorporated into the sacral fixation of CD instrumentation in seven calf spines. Specimens were loaded to simulate flexion. The sacral screws carried axial loads (1.1 N/[Nm of load]) and bending moments (1.1 Nm/[Nm of load]). The results suggest bending of the sacral screws may be important in their failure, and screw loading was not dependent on graft types used.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lumbosacral fixation using sacroiliac buttress screws: a modification to the Jackson technique with intrasacral rods

BACKGROUND The use of intrasacral rods has been previously reported for posterior lumbosacral fixation. However, problems associated with this technique include poor stability of the rod in the sacrum, difficulty in contouring the rod to fit the lateral sacral mass, and the complicated assembly procedure for the rod and pedicle screws in the thoracolumbar segments after insertion of the rod int...

متن کامل

Straight-Forward versus Bicortical Fixation Penetrating Endplate in Lumbosacral Fixation-A Biomechanical Study

OBJECTIVE Many lumbosacral fixation techniques have been described to offer a more screw-bone purchase. The forward anatomical fixation parallel to the endplate is still the most preferred method. Literature revealed little knowledge regarding the mechanical stability of lumbosacral trans-endplate fixation compared to the traditional trans-pedicular screw fixation method. The aim of this study ...

متن کامل

Complications of transpedicular lumbosacral fixation for non-traumatic disorders.

We analysed the complications encountered in 102 consecutive patients who had posterolateral lumbosacral fusion performed with transpedicular screw and rod fixation for non-traumatic disorders after a minimum of two years. Of these, 40 had spondylolysis and spondylolisthesis, 42 a degenerative disorder, 14 instability after previous laminectomy and decompression, and six pain after nonunion of ...

متن کامل

Lumbosacral Fixation Using the Diagonal S2 Screw for Long Fusion in Degenerative Lumbar Deformity: Technical Note Involving 13 Cases

Placing instrumentation into the ilium has been shown to increase the biomechanical stability and the fusion rates, but it has some disadvantages. The diagonal S2 screw technique is an attractive surgical procedure for degenerative lumbar deformity. Between 2008 and 2010, we carried out long fusion across the lumbosacral junction in 13 patients with a degenerative lumbar deformity using the dia...

متن کامل

Application of anterior debridement and reconstruction with anatomical screw-plate fixation for lumbosacral tuberculosis

This study aimed to determine the efficacy and safety of anterior debridement and reconstruction with anatomical screw-plate fixation in patients with lumbosacral junction tuberculosis (TB).A total of 48 patients (30 males and 18 females) diagnosed with lumbosacral junction TB were included in this study. All patients underwent surgery in our institution from January 2008 to July 2014, using an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Spine

دوره 18 16  شماره 

صفحات  -

تاریخ انتشار 1993