Maximum voltage gradient technique for optimization of ablation for typical atrial flutter with zero-fluoroscopy approach
نویسندگان
چکیده
Radiofrequency catheter ablation (RFCA) is an established effective method for the treatment of typical cavo-tricuspid isthmus (CTI)-dependent atrial flutter (AFL). The introduction of 3-dimensional electro-anatomic systems enables RFCA without fluoroscopy (No-X-Ray [NXR]). The aim of this study was to evaluate the feasibility and effectiveness of CTI RFCA during implementation of the NXR approach and the maximum voltage-guided (MVG) technique for ablation of AFL.Data were obtained from prospective standardized multicenter ablation registry. Consecutive patients with the first RFCA for CTI-dependent AFL were recruited. Two navigation approaches (NXR and fluoroscopy based as low as reasonable achievable [ALARA]) and 2 mapping and ablation techniques (MVG and pull-back technique [PBT]) were assessed. NXR + MVG (n = 164; age: 63.7 ± 9.5; 30% women), NXR + PBT (n = 55; age: 63.9 ± 10.7; 39% women); ALARA + MVG (n = 36; age: 64.2 ± 9.6; 39% women); and ALARA + PBT (n = 205; age: 64.7 ± 9.1; 30% women) were compared, respectively. All groups were simplified with a 2-catheter femoral approach using 8-mm gold tip catheters (Osypka AG, Germany or Biotronik, Germany) with 15 min of observation. The MVG technique was performed using step-by-step application by mapping the largest atrial signals within the CTI.Bidirectional block in CTI was achieved in 99% of all patients (P = NS, between groups). In NXR + MVG and NXR + PBT groups, the procedure time decreased (45.4 ± 17.6 and 47.2 ± 15.7 min vs. 52.6 ± 23.7 and 59.8 ± 24.0 min, P < .01) as compared to ALARA + MVG and ALARA + PBT subgroups. In NXR + MVG and NXR + PBT groups, 91% and 98% of the procedures were performed with complete elimination of fluoroscopy. The NXR approach was associated with a significant reduction in fluoroscopy exposure (from 0.2 ± 1.1 [NXR + PBT] and 0.3 ± 1.6 [NXR + MVG] to 7.7 ± 6.0 min [ALARA + MVG] and 9.1 ± 7.2 min [ALARA + PBT], P < .001). The total application time significantly decreased in the MVG technique subgroup both in NXR and ALARA (P < .01). No major complications were observed in either groups.Complete elimination of fluoroscopy is feasible, safe, and effective during RFCA of CTI in almost all AFL patients without cardiac implanted electronic devices. The most optimal method for RFCA of CTI-dependent AFL seems to be MVG; however, it required validation of optimal RFCA's parameters with clinical follow-up.
منابع مشابه
Ablation of typical atrial flutter using a novel non-fluoroscopic
1 Interv. Cardiol. (2014) 6(2), 00–00 ISSN 1755-5302 Summary Typical atrial flutter is characterized by a stable macro-reentrant circuit around the tricuspid annulus with the cavotricuspid isthmus serving as the critical zone of slow conduction. Catheter ablation targeting this isthmus provides a curative and safe treatment option for the vast majority of patients with atrial flutter. The conve...
متن کاملElectromagnetic versus fluoroscopic mapping of the inferior isthmus for ablation of typical atrial flutter: A prospective randomized study.
BACKGROUND Radiofrequency catheter ablation within the tricuspid annulus-inferior caval vein isthmus can cure typical atrial flutter. The target for ablation, nonetheless, is relatively wide, and standard ablation procedures may require significant exposure to radiation. METHODS AND RESULTS A total of 50 patients (mean age, 58+/-11 years) with typical atrial flutter were prospectively randomi...
متن کاملRadiation exposure during catheter ablation of atrial fibrillation.
BACKGROUND The purpose of this study was to determine the radiation exposure during catheter ablation of atrial fibrillation (AF) using the pulmonary vein (PV) approach. METHODS AND RESULTS The study included 15 patients with AF and 5 patients each with atrial flutter and atrioventricular nodal reentrant tachycardia (AVNRT) who underwent fluoroscopically guided procedures on a biplane x-ray s...
متن کاملFlutter ablation with remote magnetic navigation: comparison between the 8-mm tip, the irrigated tip and a manual approach.
INTRODUCTION Remote magnetic navigated ablation has proven its feasibility in a large group of arrhythmias. Until now only scarce data are available on the use for atrial flutter. In this study we compared remote magnetic navigation (RMN), using non-irrigated and irrigated tip catheters, to manual radiofrequency ablation for ablating typical atrial flutter. METHODS The 3 study groups consiste...
متن کاملA new electrocardiographic algorithm to differentiate upper loop re-entry from reverse typical atrial flutter.
OBJECTIVES This study was performed to differentiate upper loop re-entry (ULR) from reverse typical atrial flutter (AFL). BACKGROUND Right atrial ULR and reverse typical AFL have different mechanisms and ablation strategies, but similar electrocardiographic characteristics. METHODS This study included 26 patients with reverse typical AFL and 20 patients with ULR. The noncontact mapping syst...
متن کامل