RE-PERG, a new procedure for electrophysiologic diagnosis of glaucoma that may improve PERG specificity

نویسندگان

  • Alberto Mavilio
  • Dario Sisto
  • Paolo Ferreri
  • Nicola Cardascia
  • Giovanni Alessio
چکیده

PURPOSE A significant variability of the second harmonic (2ndH) phase of steady-state pattern electroretinogram (SS-PERG) in intrasession retest has been recently described in glaucoma patients (GP), which has not been found in healthy subjects. To evaluate the reliability of phase variability in retest (a procedure called RE-PERG or REPERG) in the presence of cataract, which is known to affect standard PERG, we tested this procedure in GP, normal controls (NC), and cataract patients (CP). METHODS The procedure was performed on 50 GP, 35 NC, and 27 CP. All subjects were examined with RE-PERG and SS-PERG and also with spectral domain optical coherence tomography and standard automated perimetry. Standard deviation of phase and amplitude value of 2ndH were correlated by means of one-way analysis of variance and Pearson correlation, with the mean deviation and pattern standard deviation assessed by standard automated perimetry and retinal nerve fiber layer and the ganglion cell complex thickness assessed by spectral domain optical coherence tomography. Receiver operating characteristics were calculated in cohort populations with and without cataract. RESULTS Standard deviation of phase of 2ndH was significantly higher in GP with respect to NC (P<0.001) and CP (P<0.001), and it correlated with retinal nerve fiber layer (r=-0.5, P<0.001) and ganglion cell complex (r=-0.6, P<0.001) defects in GP. Receiver operating characteristic evaluation showed higher specificity of RE-PERG (86.4%; area under the curve 0.93) with respect to SS-PERG (54.5%; area under the curve 0.68) in CP. CONCLUSION RE-PERG may improve the specificity of SS-PERG in clinical practice in the discrimination of GP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pattern electroretinogram in glaucoma suspects: new findings from a longitudinal study.

PURPOSE Early detection of glaucoma remains a challenging problem and needs long-term, prospective studies. The pattern electroretinogram (PERG) directly reflects retinal ganglion cell function. The PERG was evaluated by extending a prospective study of patients with ocular hypertension and evaluated amplitude, PERG ratio, peak time, and trends thereof. METHODS One hundred twenty eyes of 64 p...

متن کامل

Visual electrodiagnosis in glaucoma screening: a clinical study.

BACKGROUND The aim of the present study was to investigate the value of pattern visual-evoked potentials (pVEP) and pattern electroretinograms (pERG) in early glaucoma diagnosis. MATERIALS AND METHODS Thirty-eight eyes of 38 patients were included. Patients were classified into normal control (NC) and glaucoma patient (GP) groups. Patients underwent a detailed clinical ophthalmic examination ...

متن کامل

Update on the pattern electroretinogram in glaucoma.

PURPOSE To review the efficacy of the pattern electroretinogram (PERG) in early diagnosis of glaucoma. METHODS Stimulation parameters of check size and temporal frequency are considered. Analyses of various peaks (P50, N95, the N95/P50) and Fourier steady-state are considered. The relation to visual field defects is explored. RESULTS The PERG is markedly alterated in glaucoma. It shows ampl...

متن کامل

A spatial frequency-doubling illusion-based pattern electroretinogram for glaucoma.

PURPOSE A pattern electroretinogram (PERG) in which stimuli displaying the frequency-doubling (FD) illusion are presented simultaneously to multiple parts of the visual field was evaluated for its ability to diagnose glaucoma. This multiregion FD PERG is referred to in the current study as the MFP. METHODS The nine stimulus regions were temporally modulated at incommensurate frequencies typic...

متن کامل

Photopic negative response versus pattern electroretinogram in early glaucoma.

PURPOSE Photopic negative response (PhNR) and pattern electroretinogram (PERG) are electrophysiological markers of retinal ganglion cell function; both are reduced in glaucoma. We compared PhNR and PERG in different stages of the disease. METHODS Eleven eyes with preperimetric glaucoma (glaucomatous optic disc with normal field); 18 with manifest glaucoma; and 26 normals were included. We obt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2017