Morphological characterization of a polymeric microfiltration membrane by synchrotron radiation computed microtomography

نویسندگان

  • Jean-Christophe Remigy
  • Martine Meireles
  • Xavier Thibault
  • M. Meireles
  • X. Thibault
چکیده

Most commercial polymeric membranes are prepared by phase inversion. The performance of the membranes depends greatly on the morphology of the porous structure formed during the different steps of this process. Researchers in this field have found it extremely difficult to foresee how a change in the composition of the polymer solution will affect pore formation without a set of methods designed to yield detailed knowledge of the morphological structure. This paper reports the new potential associated with X-Ray synchrotron microtomography to characterize the 3D structure of a PvDF hollow fibre microfiltration membrane prepared by phase inversion. 3D morphological data obtained from the ID19 line at the ESRF are presented. The membrane actually appears as a complex three-dimensional bi-continuum of interconnected pores. Within the hollow fibre structure, different regions with various thicknesses and pore size distributions have been identified and well characterized. Transversal views show the anisotropic finger-like structure of pores, while longitudinal sections reveal a honeycomb structure which resembles the structure of highly concentrated water in oil emulsion or dispersion. This typical structure might be obtained during the phase inversion process. How the phase inversion process may result in these morphologies is finally discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preparation and Characterization of Microfiltration Membrane Embedded with Silver Nano-Particles

The microfiltration 0.2 µm Cellulose Acetate (CA) membrane was modified by embedding antibacterial silver nano-particles in the membrane pores. This novel technique was developed to enhance the capability of the microfiltration membrane for removing microorganism including bacteria. The prepared membrane was characterized using Scanning Electron Microscopy (SEM), Energy-Dispersive X-ray Spe...

متن کامل

Synchrotron radiation X-ray microfluorescence techniques and biological applications

Synchrotron X-ray imaging systems with fluorescence techniques was developed for biomedical researches in Brazilian Synchrotron Laboratory. An X-ray fluorescence microtomography system was implemented to analyse human prostate and breast samples and an X-ray microfluorescence system was implemented to study bone sites of human and animal samples with and without bone disorders.

متن کامل

Applications of X-ray synchrotron microtomography for non-destructive 3D studies of paleontological specimens

Paleontologists are quite recent newcomers among the users of X-ray synchrotron imaging techniques at the European Synchrotron Radiation Facility (ESRF). Studies of the external morphological characteristics of a fossil organism are not sufficient to extract all the information for a paleontological study. Nowadays observations of internal structures become increasingly important, but these obs...

متن کامل

In situ 3D topographic and shape analysis by synchrotron radiation X-ray microtomography for crystal form identification in polymorphic mixtures

Polymorphism denotes the existence of more than one crystal structure of a substance, and great practical and theoretical interest for the chemical and pharmaceutical industries. In many cases, it is challenging to produce a pure crystal form and establish a sensitive detection method for the identification of crystal form in a mixture of polymorphs. In this study, an accurate and sensitive met...

متن کامل

Microwave-induced thermoacoustic computed tomography with a clinical contrast agent of NMG2[Gd(DTPA)]

Related Articles Effects of signal diffusion on x-ray phase contrast images Rev. Sci. Instrum. 82, 073702 (2011) Lateral tomographic spatial frequency modulated imaging Appl. Phys. Lett. 98, 211115 (2011) Image reconstruction from sparse data in synchrotron-radiation-based microtomography Rev. Sci. Instrum. 82, 043706 (2011) Interlaced phase stepping in phase-contrast x-ray tomography Appl. Phy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008