Extracranial measurement of regional cerebral circulation.
نویسندگان
چکیده
THE INFLUENCE OF PREVIOUS LUMBAR PUNCTURE AND PNEUMOENCEPHALOGRAPHY ON THE INCIDENCE OF UNSUCCESSFUL RADIOISOTOPE CISTERNOGRAPHY Steven M. Larson, Gerald L. Schall and Giovanni Di Ghiro 555 157Dy-HEDTA FOR SKELETAL IMAGING G. Subramanian, J. G. McAfee, R. J. Blair, R. E. O'Mara, M. W. Greene, and E. Lebowitz 558 RAPID CLOSED-SYSTEM PRODUCTION OF 99mTc-ALBUMIN USING ELECTROLYSIS H. J. Dworkin and R. F. Gutkowski 562 DISTRIBUTION OF 75Se-SELENOMETHIONINE AS INFLUENCED BY THE ROUTE OF ADMINISTRATION Leonard A. Graham, Roger L. Veatch and Ervin Kaplan 566
منابع مشابه
Cerebral blood flow asymmetry in the detection of extracranial cerebrovascular disease.
Regional cerebral blood flow was measured by the 133Xe inhalation technique in patients with unilateral carotid occlusion, unilateral carotid occlusion and contralateral carotid stenosis, bilateral carotid occlusion, or normal arteriograms. After adjusting for age, sex, and history of stroke, hemispheric blood flow asymmetry was shown to be a predictor of unilateral carotid occlusion with a sen...
متن کاملCinefluorographic Studies of the Extracranial Cerebral Circulation.
RECENT INTEREST in the surgical treatment of occlusive lesions in the extracranial cerebral circulation has stimulated the development of new angiographic technics for visualizing the extracranial cerebral vessels. Since the cerebral circulation often functions as a unit, the adequacy of blood flow through all, not just one, of the major arteries supplying the brain must be known before surgica...
متن کاملImproved Method for Noninvasive Measurement of Regional Cerebral Blood Flow
A clinical method for noninvasive measurement of regional cerebral blood flow (rCBF) and blood volume (rCBV) is described, based on Obrist's 10 minute, desaturation method after 1 minute inhalation of Xe. Sixteen collimated probes are placed over both hemispheres and brain stem-cerebellar regions. End-tidal Xe curves are used for correction of recirculation. KEV discriminators are set to record...
متن کاملImpact of extracranial contamination on regional cerebral oxygen saturation: a comparison of three cerebral oximetry technologies.
BACKGROUND Cerebral oximetry is a noninvasive technology using near-infrared spectroscopy (NIRS) to estimate regional cerebral oxygen saturation. Although NIRS cerebral oximetry is being increasingly used in many clinical settings, interdevice technologic differences suggest potential variation in the ability to accurately acquire brain oxygenation signals. The primary objective of this study w...
متن کاملPost-Coronary Artery Bypass Grafting Stroke
In this issue of the Journal, Lee et al. (1) report findings from 1,367 consecutive cases of coronary artery bypass grafting (CABG) performed between 2004 and 2007 at the Asan Medical Center in Seoul, South Korea, all of whom underwent pre-operative magnetic resonance angiography (MRA) of the carotid and cerebral arteries as part of a research protocol. A total of 33 post-operative strokes were...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 12 8 شماره
صفحات -
تاریخ انتشار 1971