A wind-tunnel study of flow distortion at a meteorological sensor on top of the BT Tower, London, UK
نویسندگان
چکیده
High quality wind measurements in cities are needed for numerous applications including wind engineering. Such data-sets are rare and measurement platforms may not be optimal for meteorological observations. Two years’ wind data were collected on the BT Tower, London, UK, showing upward deflection for all wind directions. Wind tunnel simulations were performed to investigate flow distortion around two scale models of the Tower. Using a 1:160 scale model it was shown that the Tower causes a small deflection (c. 0.5°) compared to the lattice on top on which the instruments were placed (c. 0 to 4°). These deflections may have been underestimated due to wind tunnel blockage. Using a 1:40 model, the observed flow pattern was consistent with streamwise vortex pairs shed from the upstream lattice edge. Correction factors were derived for different wind directions and reduced deflection in the full-scale data-set by < 3°. Instrumental tilt caused a sinusoidal variation in deflection of c. 2°. The residual deflection (c.3°) was attributed to the Tower itself. Correction of the wind-speeds was small (average 1%) therefore it was deduced that flow distortion does not significantly affect the measured wind-speeds and the wind climate statistics are reliable. Manuscript Click here to view linked References
منابع مشابه
Experimental and numerical study of natural ventilation in four-sided wind tower traps
In the past, wind towers were applied as the main architectural part of building construction in the desert areas of Iran. These almost high structures were used as cooling load suppliers at residential buildings. In the present study, the effect of symmetric four-sided wind tower in flow induction to the bottom space has been analysed by using a wind tunnel and numerical simulations. In the nu...
متن کاملStudy of Degradation of Dry Cooling Tower Performance under Wind Conditions and Method for Tower Efficiency Enhancement (RESEARCH NOTE)
Wind affects adversely the cooling tower thermal performance. A field investigation was carried out to study the thermal performance of Heller cooling towers under wind conditions, involving measurement of wind velocity and its direction around the cooling tower, and obtaining water flow rates and temperatures at the cooling tower inlet and outlet. Results show that air suction at the tower top...
متن کاملOptimal Height for a Wind Tower on a Building in Yazd
Wind is one of the cleanest and cheapest renewable energies. One of the wind energy production technologies is use of small wind turbines installed in urban areas. However, installing these turbines in urban areas is associated with problems such as low wind speed and turbulence but if installed in the wrong location, their generated electricity is zero. In this study for the use of wind energy...
متن کاملInvestigation of Vertical Wind Shear Characteristics Using 50m Meteorological Tower Data
Wind measurement is important for estimating wind energy potential, but it is relatively cost-intensive and often conducted at a narrow height from the ground level. The typical range of most turbine hub heights is from 30-50 m or even higher. Extrapolation on wind data thus becomes necessary to estimate the wind speed at different heights. Doing so requires the essential understanding of wind ...
متن کاملEffect of Wind on Thermal Performance of Heller Dry Cooling Tower
In a steam power plant, the temperature of the cooling water leaving the condenser for recyclingshould decrease. This is achieved in a cooling tower. The Heller cooling tower does not require waterfor operation, thus, it is a suitable system for use in thermal power plants throughout Iran. Wind is anenvironmental factor that unfavorably affects the performance of a cooling tower. Previous studi...
متن کامل