Evaluation of alpha-methylacyl-CoA racemase, metallothionein and prostate specific antigen as prostate cancer prognostic markers.
نویسندگان
چکیده
Current diagnostic techniques are inefficient in distinguishing latent and low-risk forms of prostate cancer from high-risk forms. The present study is focused on determination of putative tumor markers of aggressive high-grade forms of prostate cancer. Potential markers were determined in blood sera of 133 patients (82 cases and 51 controls) and in cell lines (Gleason score 9-derived 22Rv1 and normal tissue derived PNT1A) on mRNA and protein levels. Alpha-methylacyl-CoA racemase (AMACR), metallothionein classes 1A and 2A (MT1A and MT2A) were determined and compared to prostate specific antigen (PSA) levels. On mRNA level, significantly increased expression of MT2A (2.4-fold), PSA (2.6-fold) and AMACR (8.4-fold) and insignificantly (1.9-fold) elevated MT1A in 22Rv1 compared to non-tumor PNT1A were determined. On protein level, significant enhancement of free PSA and total PSA in tumor cell line was evident. AMACR protein was 1.5-fold elevated in tumor line (below the level of significance). Contrary to mRNA, significantly (p = 0.01) reduced level of MT protein in tumor lines was determined. In the case of serum level, significantly enhanced MT level (4.5-fold) in patients' sera was found. No significant changes were observed in the case of AMACR. These findings indicate possible alternative role of MT to PSA prostate cancer marker. In addition, level of AMACR is distinctly higher in the Gleason score 9 in serum of patients and MT shows a descending trend in relation to Gleason score.
منابع مشابه
Decreased alpha-methylacyl CoA racemase expression in localized prostate cancer is associated with an increased rate of biochemical recurrence and cancer-specific death.
Alpha-methylacyl CoA racemase (AMACR) is overexpressed in prostate cancer relative to benign prostatic tissue. AMACR expression is highest in localized prostate cancer and decreases in metastatic prostate cancer. Herein, we explored the use of AMACR as a biomarker for aggressive prostate cancer. AMACR protein expression was determined by immunohistochemistry using an image analysis system on tw...
متن کاملAdvances in biomarkers for the early diagnosis of prostate cancer.
More and more studies have revealed that the level of serum prostate specific antigen(PSA) has little value for early diagnosis of prostate cancer (PCa). For example, negative prostate biopsies are as high as 70%-80% for patients with serum PSA ranging between 4 ng/mL and 10 ng/mL. However, the negative results cannot exclude the existence of cancer. In the studies of the early diagnosis of PCa...
متن کاملLipid metabolism in prostate cancer.
The malignant transformation of cells requires adaptations across multiple metabolic processes to satisfy the energy required for their increased rate of proliferation. Dysregulation of lipid metabolism has been a hallmark of the malignant phenotype; increased lipid accumulation secondary to changes in the levels of a variety of lipid metabolic enzymes has been documented in a variety of tumors...
متن کاملHumoral Immune Response to -Methylacyl-CoA Racemase and Prostate Cancer
Background: Although prostate-specific antigen (PSA) is a prototypic biomarker for prostate cancer, it has poor specificity. Expression of -methylacyl-CoA racemase (AMACR), which is involved in the conversion of Rstereoisomers of branched-chain fatty acids to S-stereoisomers, has been shown to be specifically increased in prostate cancer epithelia. However, attempts to detect AMACR in circulati...
متن کاملDetection of Alpha-Methylacyl-CoA Racemase (AMACR), a Biomarker of Prostate Cancer, in Patient Blood Samples Using a Nanoparticle Electrochemical Biosensor
41 Background: A promising prostate cancer biomarker, alpha-methylacyl-CoA racemase (AMACR), has demonstrated the ability to distinguish cancer from healthy and benign cells with high sensitivity and specificity. However the lack of a good clinical assay has limited its translation into the clinic. Here we report on the development of a single use disposable biosensor for AMACR detection. MET...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Neoplasma
دوره 59 2 شماره
صفحات -
تاریخ انتشار 2012