Simulation of Control of Multi-variable Control Loop: Steam Turbine
نویسندگان
چکیده
Abstract The paper deals with the description and simulation verification of one of possible methods to control of multivariable control loops. In this case, the so called main controllers, binding members and correction members are used. The proposed method of control combines classical way to ensure of autonomy of control loop via binding members and the use of the method of single-variable branched control loops with measurement of dominant disturbance variables to ensure of invariance of control loop via correction members. Main controllers can be proposed by arbitrary synthesis method. Simulation verifications of the control method are carried out for three-variable loop of a steam turbine. (Received in April 2010, accepted in January 2011. This paper was with the authors 1 month for 1 revision.)
منابع مشابه
Simple Approach to Solution of Autonomy and Invariance of Mimo Control Loops: Simulation Control of Three-variable System of Steam Turbine
Pavel Navrátil, Jaroslav Balátě & Tomas Sysala Tomas Bata University in Zlín, Faculty of Applied Informatics Nad Stráněmi 4511, 760 05 Zlín Czech Republic ABSTRACT This paper describes one of possible way to control of MIMO control loop with utilisation of the so called binding members and correction members. The designed method combinations classical way to ensure of autonomy of control loop v...
متن کاملModeling, Simulation and Control of Matrix Convert for Variable Speed Wind Turbine System
This paper presents modeling, simulation and control of matrix converter (MC) for variable speed wind turbine (VSWT) system including permanent magnet synchronous generator (PMSG). At a given wind velocity, the power available from a wind turbine is a function of its shaft speed. In order to track maximum power, the MC adjusts the PMSG shaft speed.The proposed control system allowing independen...
متن کاملPerformance Comparison between Steam Injected Gas Turbine and Combined Cycle during Frequency Drops
Single-shaft gas turbine and its cycles are sensitive to frequency drops and, therefore, sudden change loads or large frequency dips might affect their stability. This phenomenon is related to the reduction of the air mass flow passing through the machine during the frequency dips, which might lead to an interaction between governor and temperature control loop. In this paper, the performance o...
متن کاملDesign and Simulation of Double Loop Control for Power Converter Fed Variable Speed DC Drive
متن کامل
Control Reconfiguration of a Boiler-Turbine Unit After Actuator Faults
Boiler-turbines are one of the most important parts in power generation plants. The safety problem in such systems has always been a special concern. This paper discusses the application of control reconfig uration by fault-hiding approach for a boiler-turbine unit. In Fault-hiding approach, after occurrence of a fault, nominal controller of the system remains unchanged; instead, a reconfigurat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -