Optimizing standard cardiopulmonary resuscitation with an inspiratory impedance threshold valve.

نویسندگان

  • K G Lurie
  • K A Mulligan
  • S McKnite
  • B Detloff
  • P Lindstrom
  • K H Lindner
چکیده

OBJECTIVES This study was designed to assess whether intermittent impedance of inspiratory gas exchange improves the efficiency of standard cardiopulmonary resuscitation (CPR). BACKGROUND Standard CPR relies on the natural elastic recoil of the chest to transiently decrease intrathoracic pressures and thereby promote venous blood return to the heart. To further enhance the negative intrathoracic pressures during the "relaxation" phase of CPR, we tested the hypothesis that intermittent impedance to inspiratory gases during standard CPR increases coronary perfusion pressures and vital organ perfusion. METHODS CPR was performed with a pneumatically driven automated device in a porcine model of ventricular fibrillation. Eight pigs were randomized to initially receive standard CPR alone, while seven pigs initially received standard CPR plus intermittent impedance to inspiratory gas exchange with a threshold valve set to -40 cm H2O. The compression:ventilation ratio was 5:1 and the compression rate was 80/min. At 7-min intervals the impedance threshold valve (ITV) was either added or removed from the ventilation circuit such that during the 28 min of CPR, each animal received two 7-min periods of CPR with the ITV and two 7-min periods without the valve. RESULTS Vital organ blood flow was significantly higher during CPR performed with the ITV than during CPR performed without the valve. Total left ventricular blood flow (mean+/-SEM) (mL/min/g) was 0.32+/-0.04 vs 0.23+/-0.03 without the ITV (p<0.05). Cerebral blood flow (mL/min/g) was 20% higher with the ITV (+ITV, 0.23+/-0.02; -ITV, 0.19+/-0.02; p<0.05). Each time the ITV was removed, there was a statistically significant decrease in the vital organ blood flow and coronary perfusion pressure. CONCLUSIONS Intermittent impedance to inspiratory flow of respiratory gases during standard CPR significantly improves CPR efficiency during ventricular fibrillation. These studies underscore the importance of lowering intrathoracic pressures during the relaxation phase of CPR.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Utilization of a model lung system to assess the effects of an inspiratory impedance threshold valve on the relationship between active decompression and intra-thoracic pressure.

Use of an inspiratory impedance valve has recently been shown to increase the efficacy of standard and active compression-decompression cardiopulmonary resuscitation. We evaluated the effects of a prototypic impedance valve on the relationship between the active decompression and intra-thoracic pressure using a mechanical model lung system. Intermittent impedance to inspiratory flow of respirat...

متن کامل

Use of an inspiratory impedance threshold valve during cardiopulmonary resuscitation: a progress report.

Building upon studies on the mechanism of active compression-decompression (ACD) cardiopulmonary resuscitation, a new inspiratory impedance threshold valve has been developed to enhance the return of blood to the thorax during the decompression phase of CPR. Use of this device results in a greater negative intrathoracic pressure during chest wall decompression. This leads to improved vital orga...

متن کامل

Evaluation of a prototypic inspiratory impedance threshold valve designed to enhance the efficiency of cardiopulmonary resuscitation.

OBJECTIVE Assess a prototype inspiratory impedance threshold valve (ITV) designed to enhance vital organ circulation during standard and active compression/decompression cardiopulmonary resuscitation (CPR). BACKGROUND The ITV attaches to commonly used airway assist devices and decreases intrathoracic pressure during the decompression (chest recoil) phase of CPR by creating a vacuum within the...

متن کامل

Evaluation of an impedance threshold device in patients receiving active compression-decompression cardiopulmonary resuscitation for out of hospital cardiac arrest.

AIMS The purpose of this multicentre clinical randomized controlled blinded prospective trial was to determine whether an inspiratory impedance threshold device (ITD), when used in combination with active compression-decompression (ACD) cardiopulmonary resuscitation (CPR), would improve survival rates in patients with out-of-hospital cardiac arrest. METHODS AND RESULTS Patients were randomize...

متن کامل

Clinical Investigations Clinical evaluation of an inspiratory impedance threshold device during standard cardiopulmonary resuscitation in patients with out-of-hospital cardiac arrest*

An inspiratory impedance threshold device (ITD) has recently been demonstrated to enhance vital organ perfusion and neurologically intact survival rates in animals in cardiac arrest during standard cardiopulmonary resuscitation (CPR) (1– 4). The ITD is a small, 35-mL device that can attach to a variety of airway adjuncts, including a facemask and endotracheal tube (Fig. 1). By selectively imped...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 113 4  شماره 

صفحات  -

تاریخ انتشار 1998