Creation of plasma density transitions short compared to the plasma skin depth
نویسندگان
چکیده
A plasma based electron beam source apparatus is described which creates a plasma with two distinct density regions separated by a transition which is shorter than the plasma skin depth kp −1 of either region. This sharp density modulation is achieved by using a perforated stainless steel screen to filter half of a diffusing plasma column. A simple physical model predicts that the length of the plasma density transition will vary with the distance from the screen. For a weakly magnetized plasma, the transition length will be twice the distance, on a line normal to the screen plane, from the screen edge to the location where the transition is measured. The plasma column is generated using an argon discharge plasma source. It has a peak density of approximately 3.531013 cm−3 and a full width half maximum width of 5 cm. The discharge source utilizes a 7.5 cm diameter LaB6 disk cathode heated to 1300 °C using a graphite heater. The plasma column is filtered with a 78 mm thick stainless steel sheet with 152 mm holes and 21% open area. Plasma density transitions with lengths between 0.74 and 0.95kp −1 were measured. © 2005 American Institute of Physics. [DOI: 10.1063/1.1829996]
منابع مشابه
Fabrication of Nanostructured Cu matrix Nanocomposites by High Energy Mechanical Milling and Spark Plasma Sintering
Spark plasma sintering (SPS) is a sintering process that is capable of sintering hard worked powders in short times. This technique was used to fabricate bulk Cu and Cu-SiC nanocomposites. Pure Cu and mixed powders of Cu including 4 vol% of SiC nanoparticles were mechanically alloyed for 25 h and sintered at 750˚C under vacuum condition by SPS method. Microstructures of the materials were chara...
متن کاملEffect of Pyramidal Training on Plasma Lipid Profile and Fibrinogen, and Blood Viscosity of Untrained Young Men
The present study examined the effects of progressive exercise (pyramidal) short-term program on plasma fibrinogen, lipid profile and blood viscosity in untrained young men. Changes and imbalances in homeostasis lead to cause of heart attacks. There is conflicting information about the effect of exercise on these factors. 19 young healthy untrained men were randomly assigned to the exercise gro...
متن کاملDebye length and plasma skin depth: two length scales of interest in the creation and diagnosis of laboratory pair plasmas
In traditional electron/ion laboratory plasmas, the system size L is much larger than both the plasma skin depth ls and the Debye length λD. In current and planned efforts to create electron/positron plasmas in the laboratory, this is not necessarily the case. A low-temperature, low-density system may have λD < L< ls; a high-density, thermally relativistic system may have ls < L < λD. Here we c...
متن کاملInverse Braking Radiation and Resonance Absorption in Corona Plasmas of Inertial Confinement Fusion
Abstract: In this paper, combining the Maxwell equations with the electron balanceequation, we obtain the inverse braking radiation absorption coefficient in a laser fusioncorona plasma. For a fixed plasma temperature, variations of the absorption coefficientversus the penetration depth into the plasma are illustrated numerically for differentvalues of laser wavelength. ...
متن کاملTransparency of overdense plasma with V shape density profile
In this study, we investigate the transparency of an overdense inhomogeneous plasma slab. This anomalous transmission is achieved when the conditions provided for the incident electromagnetic wave to excite coupled surface waves on the both sides of the slab. These conditions require that the homogeneous overdense plasma, or the metallic film, is placed between two dielectric layers. Here, the ...
متن کامل