Highly accelerated T1-weighted abdominal imaging using 2-dimensional controlled aliasing in parallel imaging results in higher acceleration: a comparison with generalized autocalibrating partially parallel acquisitions parallel imaging.
نویسندگان
چکیده
PURPOSE The purpose of this study was to evaluate the feasibility and technical quality of an abdominal 3-dimensional interpolated breath-hold (volumetric interpolated breath-hold examination [VIBE]) magnetic resonance examination using the new parallel acquisition technique, controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA). MATERIALS AND METHODS In this institutional review board-approved study, 15 volunteers underwent an abdominal magnetic resonance imaging examination including axial unenhanced 3-dimensional VIBE sequences with the conventional parallel acquisition technique, generalized autocalibrating partially parallel acquisitions parallel imaging (GRAPPA), with an acceleration factor (R) of 2, 3, 4, and 2 × 2 in comparison with a CAIPIRINHA-VIBE sequence with an acceleration factor of 2 × 2. Images were evaluated regarding the overall image quality, liver edge sharpness, and parallel imaging artifacts. Signal-to-noise ratio was evaluated using 2 different methods. In a second study population, 17 patients were examined with our new routine protocol for abdominal imaging that now comprises VIBE sequences with CAIPIRINHA with R = 2 × 2. RESULTS In the volunteer population, the overall image quality of CAIPIRINHA with R = 2 × 2 was significantly higher compared with GRAPPA with R = 3, 4, and 2 × 2 (P < 0.05). There were significantly less parallel imaging artifacts with CAIPIRINHA with R = 2 × 2 (P < 0.05). Acquisition time varied between 21.1 (GRAPPA with R = 2, 320 matrix) and 6.9 seconds (CAIPIRINHA with R = 2 × 2, 256 matrix). Signal-to-noise ratio performance of CAIPIRINHA with R = 2 × 2 was superior to GRAPPA with R = 3, 4, and 2 × 2. In the patient population, VIBE sequences with CAIPIRINHA with R = 2 × 2 showed consistently good image quality, minimal motion artifacts, and minimal parallel imaging artifacts. CONCLUSIONS The CAIPRINHA-VIBE with an acceleration factor of R = 2 × 2 is feasible in a clinical setting and is characterized by fast and robust imaging with an image quality comparable with a 2-fold acceleration with GRAPPA.
منابع مشابه
Magnetic Resonance in Medicine 63:502–509 (2010) IIR GRAPPA for Parallel MR Image Reconstruction
Accelerated parallel MRI has advantage in imaging speed, and its image quality has been improved continuously in recent years. This paper introduces a two-dimensional infinite impulse response model of inverse filter to replace the finite impulse response model currently used in generalized autocalibrating partially parallel acquisitions class image reconstruction methods. The infinite impulse ...
متن کاملComparison of generalized autocalibrating partially parallel acquisitions and modified sensitivity encoding for diffusion tensor imaging.
BACKGROUND AND PURPOSE Diffusion tensor magnetic resonance imaging (DTI) of the brain is usually acquired with single-shot echo-planar imaging, which is associated with localized signal loss, geometric distortions, and blurring. Parallel imaging can lessen these artifacts by shortening the length of the echo-train acquisition. The self-calibrating parallel acquisition techniques, image domain-b...
متن کاملWave-CAIPI for highly accelerated MP-RAGE imaging.
PURPOSE To introduce a highly accelerated T1-weighted magnetization-prepared rapid gradient echo (MP-RAGE) acquisition that uses wave-controlled aliasing in parallel imaging (wave-CAIPI) encoding to retain high image quality. METHODS Significant acceleration of the MP-RAGE sequence is demonstrated using the wave-CAIPI technique. Here, sinusoidal waveforms are used to spread aliasing in all th...
متن کاملParallel imaging with phase scrambling.
PURPOSE Most existing methods for accelerated parallel imaging in MRI require additional data, which are used to derive information about the sensitivity profile of each radiofrequency (RF) channel. In this work, a method is presented to avoid the acquisition of separate coil calibration data for accelerated Cartesian trajectories. METHODS Quadratic phase is imparted to the image to spread th...
متن کاملAccelerating time-resolved MRA with multiecho acquisition.
A new four-dimensional magnetic resonance angiography (MRA) technique called contrast-enhanced angiography with multiecho and radial k-space is introduced, which accelerates the acquisition using multiecho while maintaining a high spatial resolution and increasing the signal-to-noise ratio (SNR). An acceleration factor of approximately 2 is achieved without parallel imaging or undersampling by ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative radiology
دوره 48 7 شماره
صفحات -
تاریخ انتشار 2013