Retrospective case study of carbon dioxide laser stapedotomy with lens-based and mirror-based micromanipulators.
نویسندگان
چکیده
Most clinical studies on carbon dioxide (CO2) (lambda = 10.6 mm) laser stapedotomy have been carried out with the laser guided by a conventional lens-based micromanipulator, with the attendant risks of correct aiming (HeNe) and surgical (CO2) beam misalignment. Hence, engineering advances have attempted to improve laser targeting as well as the spot size focus. The development of the mirror-based micromanipulator was a response to this need but no data concerning its use in stapes surgery is available. We performed a retrospective case-series review of patients treated for otosclerosis between 1992 and 2000. Primary laser stapedotomy was performed in 218 consecutive patients. In the first 78 procedures, the aiming beam (HeNe, lambda = 632 nm) and surgical beam (CO2) were guided with a conventional lens-based micromanipulator whereas in the subsequent 140 procedures, they were guided by using a mirror-based micromanipulator. Hearing was tested at six and 12 months. The mean (SD) airbone gap was 5 dB (4.5) and 4.5 dB (3.9). The mean closure was 15 dB (9.9) and 14.4 dB (9.4). The mean change in the high-tone bone-conduction level was 5.5 dB (7.3) and 7.8 dB (7.5). Overheating of the facial canal produced transient facial paralysis in one case and was due to misalignment of the beams with the lens-based micromanipulator. Use of the mirror-based micromanipulator obviated the need to verify alignment. The light-weight and superior optical yield of this system made it possible to reduce the number of impacts on the footplate by the integral restitution of the energy source. This study demonstrated that the CO2 laser is an effective method for performing stapedotomy. In addition, microtrauma to the labyrinth is reduced by its ability to perform calibrated footplate fenestration without mechanical or vibrational injury to the inner ear. The optical reflection micromanipulator simplified beam alignment and enhanced surgical comfort.
منابع مشابه
Flexible Fiber Optic Carbon-Dioxide Laser Assisted Stapedotomy in Otosclerosis
Objective. The aim of this study is to analyze the hearing and vestibular outcome of patients with otosclerosis who have been operated on by fiber optic flexible CO2 laser. Study Design. A preliminary and retrospective study was conducted in 30 patients with otosclerosis. Results. Comparative analysis of average air conduction thresholds (53.41 ± 11.81 dB versus 26.37 ± 11.04 dB) and air-bone g...
متن کاملInfluence of shielding gas composition on weld profile in pulsed Nd:YAG laser welding of low carbon steel
Weld area and weld depth/width ratio can be considered to be of the most important geometrical factors in pulsed laser welding. The effects of carbon dioxide and oxygen additions to the argon shielding gas on the weld properties in pulsed laser welding of low carbon steel is investigated. Presence of carbon dioxide and oxygen up to 10 and 15 percent respectively decreases the weld geometrical f...
متن کاملCombination Surgical Excision and Fractional Carbon Dioxide Laser for Treatment of Rhinophyma
Rhinophyma is a severe late complication of rosacea, which is characterized by progressive hyperplasia of sebaceous glands and connective tissue involving the lower two-thirds of the nose. It can be an emotionally devastating disorder, and serve as a medium for occult cancers and other health problems. Many surgical treatments have been advocated, as well as dermabrasion and laser therapy. In l...
متن کاملThermal Analysis of Laser Hardening for Different Moving Patterns
Transient thermal field in laser surface hardening treatment of medium carbon steel was analyzed by employing both three-dimensional analytical model and finite element model. In finite element model the laser beam was considered as a moving plane heat flux to establish the temperature rise distribution in the work-piece, while in analytical model laser beam was considered as an internal heat s...
متن کاملComparison of the therapeutic effect of microneedling with carbon dioxide laser in hypertrophic burn scars: a randomized clinical trial
Background: Microneedling is recently used to treat skin scars mostly atrophic scars; however, there are limited data about its effectiveness on hypertrophic burn scars. Carbon dioxide (CO2) laser is an effective method for the treatment of burn scars. Here, we aim to compare the efficacy of microneedling to CO2 laser in the treatment of hypertrophic burn scars in a randomized clinical trial. M...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of laryngology and otology
دوره 117 4 شماره
صفحات -
تاریخ انتشار 2003