Diagnostic accuracy of scanning laser polarimetry with enhanced versus variable corneal compensation.

نویسندگان

  • T A Mai
  • N J Reus
  • H G Lemij
چکیده

PURPOSE To compare the diagnostic accuracy of scanning laser polarimetry (SLP) parameters between images taken with enhanced corneal compensation (ECC) and those with variable corneal compensation (VCC) and to explore the effect of atypical birefringence patterns on this accuracy. DESIGN Cross-sectional observational study. PARTICIPANTS Forty-one healthy subjects and 92 patients with primary open-angle glaucoma. METHODS Variable corneal compensation and ECC images were obtained of 1 eye per subject, selected randomly if both eyes were eligible. For both ECC and VCC, the areas under the receiver operating characteristic curves (AUROCs) and the sensitivity at a specificity of > or =95% were calculated per parameter in all eyes. The analyses were reperformed separately in eyes with and without atypical birefringence patterns (ABP) images. MAIN OUTCOME MEASURES The AUROCs and sensitivities at a specificity of > or =95% for various SLP parameters in all eyes and in eyes without ABP images. RESULTS The diagnostic accuracy for most standard parameters (temporal-superior-nasal-inferior-temporal [TSNIT] average, superior average, inferior average, and TSNIT standard deviation) in all eyes was statistically significantly higher with ECC than with VCC, except for the nerve fiber indicator (NFI). When only eyes without ABP were used for the analysis, the diagnostic accuracy of SLP parameters with VCC improved, and the differences in diagnostic accuracy between ECC and VCC for these parameters lost their statistical significance. CONCLUSIONS Standard SLP parameters (except for the NFI) generally had a higher diagnostic accuracy when eyes were imaged with ECC than with VCC because there were fewer ABP images with ECC than with VCC. Enhanced corneal compensation therefore may be more reliable than VCC for the detection of glaucoma. A future automated classifier, similar to the current NFI, may perform better if it is trained on data obtained with ECC. Clinically, retinal nerve fiber layer images with marked ABP, acquired with either ECC or VCC, should be viewed with caution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Association between scanning laser polarimetry measurements using variable corneal polarization compensation and visual field sensitivity in glaucomatous eyes.

OBJECTIVE To compare the association between scanning laser polarimetry (SLP) retinal nerve fiber layer (RNFL) measurements and automated perimetry sensitivity using both SLP manufacturer-assumed fixed and subject-specific variable corneal polarization magnitude and corneal polarization axis values. METHODS An SLP was modified to enable the measurement of corneal polarization magnitude and co...

متن کامل

Fourier analysis of scanning laser polarimetry measurements with variable corneal compensation in glaucoma.

PURPOSE To apply Fourier analysis to the retinal nerve fiber layer (RNFL) thickness measurements obtained with scanning laser polarimetry (SLP), by using variable corneal compensation, and to evaluate the ability of this method to discriminate glaucomatous from normal eyes. METHODS The study included one eye each of 55 patients with glaucoma and 52 healthy subjects. RNFL thickness measurement...

متن کامل

Detection of glaucoma using scanning laser polarimetry with enhanced corneal compensation.

PURPOSE To evaluate and compare the diagnostic accuracies for glaucoma detection of scanning laser polarimetry (SLP) with enhanced corneal compensation (GDx ECC) and variable corneal compensation (GDx VCC; both by Carl Zeiss Meditec, Dublin, CA), according to different levels of disease severity and presence of atypical retardation patterns. METHODS The study included 102 eyes of 68 patients ...

متن کامل

Relationship between Scanning Laser Polarimetry with Enhanced Corneal Compensation and with Variable Corneal Compensation

PURPOSE To evaluate the structure-function relationships between retinal sensitivity measured by Humphrey visual field analyzer (HVFA) and the retinal nerve fiber layer (RNFL) thickness measured by scanning laser polarimetry (SLP) with variable corneal compensation (VCC) and enhanced corneal compensation (ECC) in glaucomatous and healthy eyes. METHODS Fifty-three eyes with an atypical birefri...

متن کامل

Longitudinal measurement variability of corneal birefringence and retinal nerve fiber layer thickness in scanning laser polarimetry with variable corneal compensation.

OBJECTIVE To investigate the longitudinal corneal birefringence (corneal polarization axis [CPA] and corneal polarization magnitude [CPM]) variability in scanning laser polarimetry with variable corneal compensation and its effect on retinal nerve fiber layer measurements. Method We analyzed scanning laser polarimetry images obtained every 6 months for 3.2 years in 16 healthy eyes, 38 eyes with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ophthalmology

دوره 114 11  شماره 

صفحات  -

تاریخ انتشار 2007