High-resolution ion mobility measurements

نویسندگان

  • Ph. Dugourd
  • R. R. Hudgins
  • D. E. Clemmer
  • M. F. Jarrold
چکیده

Gas phase ion mobility measurements can resolve structural isomers for polyatomic ions and provide information about their geometries. A new experimental apparatus for performing high-resolution ion mobility measurements is described. The apparatus consists of a pulsed laser vaporization/desorption source coupled through an ion gate to a 63-cm-long drift tube. The ion gate is a critical component that prevents the diffusion of neutral species from the source into the drift tube. Ions travel along the drift tube under the influence of a uniform electric field. At the end of the drift tube some of the ions exit through a small aperture. They are focused into a quadrupole mass spectrometer, where they are mass analyzed, and then detected by an off-axis collision dynode and by dual microchannel plates. The apparatus is operated with a drift voltage of up to 14 000 V and a helium buffer gas pressure of around 500 Torr. The resolving power for ion mobility measurements is over an order of magnitude higher than has been achieved using conventional injected-ion drift tube techniques. Examples of the application of the new apparatus in resolving isomers of laser desorbed metallofullerenes, in studying silicon clusters generated by laser vaporization, and in following the isomerization of small nanocrystalline ~NaCl!nCl 2 clusters as a function of temperature, are presented. © 1997 American Institute of Physics. @S0034-6748~97!01202-1#

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ion Mobility Measurements and their Applications to Clusters and Biomolecules

In this article we describe some of the recent work that has been performed using ion mobility measurements to deduce structural information for polyatomic ions. Determining the structure of a polyatomic ion in the gas phase is a challenging problem, that is usually approached by indirect methods such as dissociation or reactivity studies. Ion mobility measurements have recently emerged as a te...

متن کامل

Cluster measurements at CLOUD using a high resolution ion mobility spectrometer- mass spectrometer combination

Mass spectrometry is powerful tool for environmental and atmospheric chemistry analysis. Modern mass spectrometers demonstrate low detection limits, high sensitivity, and high resolving power. However, such high performance is not always enough to identify ambient ion clusters due to the clusters braking at the atmospheric pressure-to-vacuum interface of mass spectrometer. This study presents a...

متن کامل

High-resolution ion mobility measurements for silicon cluster anions and cations

High-resolution ion mobility measurements have been performed for silicon cluster anions and cations, Sin 2 and Sin 1 , n56 – 55. New isomers have been resolved for every cluster size larger than Si20 . The results for the anions and the cations have the same global features. However, changing the charge often causes a shift in the isomer distribution, or causes new isomers to emerge. For examp...

متن کامل

An exact hard-spheres scattering model for the mobilities of polyatomic ions

We describe an exact hard-spheres scattering model for calculating the gas phase mobilities of polyatomic ions. Ion mobility measurements have recently been used to deduce structural information for clusters and biomolecules in the gas phase. In virtually all of the previous ion mobility studies, mobilities were evaluated for comparison with the experimental data using a projection approximatio...

متن کامل

Isomer Separation of Polybrominated Diphenyl Ether Metabolites using nanoESI-TIMS-MS.

In this paper, high-resolution nano-electrospray ionization-trapped ion mobility spectrometry coupled to mass spectrometry (nESI-TIMS-MS) is used for the study of hydroxylated polybrominated diphenyl ether (OH-PBDE) metabolites. In particular, experimental ion-neutral collision cross sections (CCS) were measured for five structural OH-PBDE isomers using TIMS-MS. Candidate structures were propos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1997