Wavelength Dependence On The Level Of Post-Source Metastable Ion Decay Observed In Infrared Matrix-Assisted Laser Desorption Ionization.
نویسندگان
چکیده
The levels of post-source metastable ion decay (PSD) observed in several peptides and proteins ionized by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI TOF-MS) are measured utilizing both infrared (IR) and ultraviolet (UV) desorption wavelengths. A gridless deceleration ion optic is employed to temporally separate stable analyte ions from analyte metastable neutral and ion fragments. Comparisons of the extent of PSD that is observed in UV-MALDI at 337 nm and IR-MALDI at multiple wavelengths between 2.8 and 3.0 mum are made using the same matrices and analytes. The amount of PSD observed using IR-MALDI was found to be highly dependent on the specific IR wavelength (2.8-3.0 mum) employed for desorption. IR wavelengths shorter than 2.86 mum tended to produce higher levels of PSD, while longer IR wavelengths typically produced significantly less PSD when using a number of common MALDI matrices. Relative PSD levels are quantified by determining the percentage of the neutral fragment signal intensity to the intensity of the stable singly protonated molecular species observed in decelerated MALDI spectra. These studies suggest that an analyte ion activation pathway leading to significant PSD in IR-MALDI may proceed by way of vibrational excitation of the analyte molecules during the desorption event.
منابع مشابه
Top-Down Sequencing of Intact Proteins by MALDI In Source Decay (ISD)
Although MALDI mass spectrometry is a soft ionization technique which enables desorption of high molecular weight biomolecules exceeding several hundred kDa, it became apparent that some analyte fragmentation occurs during the MALDI process as well. The processes of fragmentation initially characterized on MALDI-TOF mass spectrometers were designated as either; (i) in-source decay (ISD), the co...
متن کاملContinuous Flow Atmospheric Pressure Laser Desorption/Ionization Using a 6–7-µm-Band Mid-Infrared Tunable Laser for Biomolecular Mass Spectrometry
A continuous flow atmospheric pressure laser desorption/ionization technique using a porous stainless steel probe and a 6-7-µm-band mid-infrared tunable laser was developed. This ion source is capable of direct ionization from a continuous flow with a high temporal stability. The 6-7-µm wavelength region corresponds to the characteristic absorption bands of various molecular vibration modes, in...
متن کاملMatrix-assisted ultraviolet laser-desorption ionization and electrospray-ionization time-of-flight mass spectrometry of sulfated neocarrabiose oligosaccharides.
Several commercial sulfated neocarrabiose oligosaccharides were analyzed by matrix-assisted ultraviolet laser-desorption ionization time-of-flight mass spectrometry (UV-MALDI-TOF-MS). UV-MALDI-TOF-MS was carried out in the linear and reflectron modes and, as routine, in both the positive- and negative-ion modes. 2,5-Dihydroxybenzoic acid and nor-harmane were used as matrices. In the positive- a...
متن کاملFundamentals of matrix-assisted laser desorption/ionization mass spectrometry with pulsed infrared lasers
The fundamental work and current knowledge on the mechanisms of matrix-assisted laser desorption ionization with pulsed infrared lasers is reviewed and discussed, with a special emphasis on the work performed in the laboratory of the authors in the recent past. The role of the different relevant irradiation parameters (laser wavelength, laser pulse duration, irradiated area and laser fluence) a...
متن کاملA comparative study of in- and post-source decays of peptide and preformed ions in matrix-assisted laser desorption ionization time-of-flight mass spectrometry: effective temperature and matrix effect.
In-source decay (ISD) and post-source decay (PSD) of a peptide ion ([Y(6) + H](+)) and a preformed ion (benzyltriphenylphosphonium, BTPP) generated by matrix-assisted laser desorption ionization (MALDI) were investigated with time-of-flight mass spectrometry. α-Cyano-4-hydroxycinammic acid (CHCA) and 2,5-dihydroxybenzoic acid (DHB) were used as matrices. For both ions, ISD yield was unaffected ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of mass spectrometry
دوره 287 1-3 شماره
صفحات -
تاریخ انتشار 2009