Noise Provides New Insights on Contrast Sensitivity Function

نویسندگان

  • Ge Chen
  • Fang Hou
  • Fang-Fang Yan
  • Pan Zhang
  • Jie Xi
  • Yifeng Zhou
  • Zhong-Lin Lu
  • Chang-Bing Huang
چکیده

Sensitivity to luminance difference, or contrast sensitivity, is critical for animals to survive in and interact with the external world. The contrast sensitivity function (CSF), which measures visual sensitivity to spatial patterns over a wide range of spatial frequencies, provides a comprehensive characterization of the visual system. Despite its popularity and significance in both basic research and clinical practice, it hasn't been clear what determines the CSF and how the factors underlying the CSF change in different conditions. In the current study, we applied the external noise method and perceptual template model to a wide range of external noise and spatial frequency (SF) conditions, and evaluated how the various sources of observer inefficiency changed with SF and determined the limiting factors underlying the CSF. We found that only internal additive noise and template gain changed significantly with SF, while the transducer non-linearity and coefficient for multiplicative noise were constant. The 12-parameter model provided a very good account of all the data in the 200 tested conditions (86.5%, 86.2%, 89.5%, and 96.4% for the four subjects, respectively). Our results suggest a re-consideration of the popular spatial vision model that employs the CSF as the front-end filter and constant internal additive noise across spatial frequencies. The study will also be of interest to scientists and clinicians engaged in characterizing spatial vision deficits and/or developing rehabilitation methods to restore spatial vision in clinical populations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Phase Noise Reduction Technique in LC Cross-coupled Oscillators with Adjusting Transistors Operating Regions

In this paper, an intuitive analysis of a phase noise reduction technique is done, and then a modified structure is proposed to achieve higher phase noise reduction than the original one. This method reduces the impact of noise sources on the phase noise by decreasing closed-loop gain in zero-crossings points and moving this high closed-loop gain to the non-zero-crossings points. This reduction...

متن کامل

Assessment of Contrast Media Volume Injected and Image Contrast in Abdominal Pelvic CT Scan and Related Factors in Referral Hospitals in Mazandaran, Iran

 Background and purpose: Computed tomography scan (CT) is highly capable of diagnosing abdominal and pelvic lesions. Injection of contrast media at appropriate concentration and volume provides the least side effects and the highest image quality. This study aimed at investigating the volume of contrast medium injected and the level of image contrast compared to the standard model, in the imagi...

متن کامل

A new approach to contrast enhancement in MAGICA gel dosimeter image with MRI technique

parameters that have to be measured in gel dosimetry. However, the resolution in gel is strongly dependant on gel composition. Selection of optimum method in dose response readout and proper values of parameters can result in noise reduction as well as improvement of contrast, and spatial resolution considerably. Materials and Methods: MAGICA polymer gel dosimeters were manufactured and irradia...

متن کامل

Sensitivity to contrast modulation: the spatial frequency dependence of second-order vision

We consider the overall shape of the second-order modulation sensitivity function (MSF). Because second-order modulations of local contrast or orientation require a carrier signal, it is necessary to evaluate modulation sensitivity against a variety of carriers before reaching a general conclusion about second-order sensitivity. Here we present second-order sensitivity functions for new carrier...

متن کامل

System Identification Based on Frequency Response Noisy Data

In this paper, a new algorithm for system identification based on frequency response is presented. In this method, given a set of magnitudes and phases of the system transfer function in a set of discrete frequencies, a system of linear equations is derived which has a unique and exact solution for the coefficients of the transfer function provided that the data is noise-free and the degrees of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014