Low kV and Low Concentration Contrast Agent with Iterative Reconstruction of Computed Tomography (CT) Coronary Angiography: A Preliminary Study

نویسندگان

  • Hong Zhang
  • Yanhe Ma
  • Jun Lyu
  • Yapeng Yang
  • Wei Yuan
  • Zhenchun Song
چکیده

BACKGROUND The aim of this study was to evaluate the image quality and radiation dose of CT coronary angiography (CTCA) with low kV, low concentration contrast agent, and iterative reconstruction. MATERIAL AND METHODS Ninety cases were randomly divided into 3 groups according to contrast agent concentration: group A 270 mg/ml (100 kV), group B 350 mg/ml (120 kV), and group C 370 mg/ml (120 kV), with 30 cases per group. Tube current was 200-250 mAs. Collimator width was 128×0.6 mm. Rotation speed was 0.27 s. The CT value of the left and right coronary arteries and the ascending aortic root was measured. The SNR and CNR of the images were calculated to evaluate the image quality objectively. The CTDI, DLP, and contrast injection were recorded. RESULTS There were no significant differences in sex, age, weight, height, and BMI among the 3 groups. There was no statistically significant difference between left and right coronary artery and ascending aortic root CT value, background noise, SNR, and CNR. Compared to B and C, the ED in group A decreased by about 27.58% and 28.21%, respectively. The total amount of iodine in group A was decreased by about 21.27% and 24.83%, respectively compared with groups B and C. CONCLUSIONS Low kV and low concentration contrast agent combined with iterative reconstruction for CTCA imaging produced image quality consistent with that of conventional CTCA and significantly reduced the dosage of the radiation and injected iodine.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low kilovolt “prospective ECG-triggering” vs. “retrospective ECG-gating” coronary CTA: comparison of image quality and radiation dose

Background: To compare image quality and radiation doses of low kilovolt (kV) “prospective ECG-triggering” (PT) and standard “retrospective ECG-gating” (RG) coronary computed tomography (CT) angiography. Materials and Methods: A total of 101 consecutive patients (76 males, 25 females; mean age: 55.44 ± 8.28 years) with low-to-intermediate risk status for coronary artery disease and with a body ...

متن کامل

Comparing IDREAM as an Iterative Reconstruction Algorithm against In Filtered Back Projection in Computed Tomography

Introduction: Recent studies of Computed Tomography (CT) conducted on patient dose reduction have recommended using an iterative reconstruction algorithm and mA (mili-Ampere) dose modulation. The current study aimed to evaluate Iterative Dose Reduction Algorithm (IDREAM) as an iterative reconstruction algorithm. Material and Methods: Two CT p...

متن کامل

Feasibility of dual-low scheme combined with iterative reconstruction technique in acute cerebral infarction volume CT whole brain perfusion imaging

The feasibility of application of low-concentration contrast agent and low tube voltage combined with iterative reconstruction in whole brain computed tomography perfusion (CTP) imaging of patients with acute cerebral infarction was investigated. Fifty-nine patients who underwent whole brain CTP examination and diagnosed with acute cerebral infarction from September 2014 to March 2016 were sele...

متن کامل

Comparison of coronary computed tomography angiography image quality with high- and low-concentration contrast agents (CONCENTRATE): study protocol for a randomized controlled trial

BACKGROUND With the development of computed tomography (CT) technology, coronary CT angiography can be acquired with low doses of radiation and contrast agent without a loss of diagnostic performance. The primary objective of the CONCENTRATE study is to prove the noninferiority of the enhancement effect of low-concentration contrast agents compared to a high-concentration contrast agent of the ...

متن کامل

Comparison of Image Quality of Low Voltage 64-slice Multidetector CT Angiography with the Standard Condition in Patients Suspected of Pulmonary Embolism

Introduction: Reduction of peak kilovoltage (kV) setting has been a useful approach to d creating radiation dose; however, it may have varied effects on noise and the accuracy of diagnosis. Thus, we compared image quality between low (80 kV) and standard kilovoltage (100 kV) protocols. Material and Methods: This triple blind non-randomized parallel quasi-experimental study was conducted on 140 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 23  شماره 

صفحات  -

تاریخ انتشار 2017