Assessment of pulmonary arterial compliance evaluated using harmonic oscillator kinematics
نویسندگان
چکیده
We hypothesized that KPA, a harmonic oscillator kinematics-derived spring constant parameter of the pulmonary artery pressure (PAP) profile, reflects PA compliance in pediatric patients. In this prospective study of 33 children (age range = 0.5-20 years) with various cardiac diseases, we assessed the novel parameter designated as KPA calculated using the pressure phase plane and the equation KPA = (dP/dt_max)2/([Pmax - Pmin])/2)2, where dP/dt_max is the peak derivative of PAP, and Pmax - Pmin is the difference between the minimum and maximum PAP. PA compliance was also calculated using two conventional methods: systolic PA compliance (sPAC) was expressed as the stroke volume/Pmax - Pmin; and diastolic PA compliance (dPAC) was determined according to a two-element Windkessel model of PA diastolic pressure decay. In addition, data were recorded during abdominal compression to determine the influence of preload on KPA. A significant correlation was observed between KPA and sPAC (r = 0.52, P = 0.0018), but not dPAC. Significant correlations were also seen with the time constant (τ) of diastolic PAP (r = -0.51, P = 0.0026) and the pulmonary vascular resistance index (r = -0.39, P = 0.0242). No significant difference in KPA was seen between before and after abdominal compression. KPA had a higher intraclass correlation coefficient than other compliance and resistance parameters for both intra-observer and inter-observer variability (0.998 and 0.997, respectively). These results suggest that KPA can provide insight into the underlying mechanisms and facilitate the quantification of PA compliance.
منابع مشابه
Periodic Solutions of the Duffing Harmonic Oscillator by He's Energy Balance Method
Duffing harmonic oscillator is a common model for nonlinear phenomena in science and engineering. This paper presents He´s Energy Balance Method (EBM) for solving nonlinear differential equations. Two strong nonlinear cases have been studied analytically. Analytical results of the EBM are compared with the solutions obtained by using He´s Frequency Amplitude Formulation (FAF) and numerical solu...
متن کاملSuper algebra and Harmonic Oscillator in Anti de Sitter space
The harmonic oscillator in anti de Sitter space(AdS) is discussed. We consider the harmonic oscillator potential and then time independent Schrodinger equation in AdS space. Then we apply the supersymmetric Quantum Mechanics approach to solve our differential equation. In this paper we have solved Schrodinger equation for harmonic oscillator in AdS spacetime by supersymmetry approach. The shape...
متن کاملNumerical Solution of the Controlled Harmonic Oscillator by Homotopy Perturbation Method
The controlled harmonic oscillator with retarded damping, is an important class of optimal control problems which has an important role in oscillating phenomena in nonlinear engineering systems. In this paper, to solve this problem, we presented an analytical method. This approach is based on the homotopy perturbation method. The solution procedure becomes easier, simpler and mor...
متن کاملSome geometrical properties of the oscillator group
We consider the oscillator group equipped with a biinvariant Lorentzian metric. Some geometrical properties of this space and the harmonicity properties of left-invariant vector fields on this space are determined. In some cases, all these vector fields are critical points for the energy functional restricted to vector fields. Left-invariant vector fields defining harmonic maps are...
متن کاملKinematics parameter extraction of longitudinal movement of common carotid arterial wall in healthy and atherosclerotic subjects based on consecutive ultrasonic image processing
Introduction:In this study, a non-invasive method based on consecutive ultrasonic image processing is introduced to assess time rate changes of the carotid artery wall displacement, velocity and acceleration in the longitudinal direction. The application of these parameters to discriminate healthy and atherosclerotic arteries was evaluated. Methods:Longitudinal displacement rate of common ...
متن کامل